`BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC)
`BOARD AND CODE ADMINISTRATION DIVISION
`
`NOTICE OF ACCEPTANCE (NOA)
`Fast Felt Corporation
`11302 Memorial Drive
`Houston, TX 77024
`
`MIAMI-DADE COUNTY
`PRODUCT CONTROL SECTION
`11805 SW 26 Street, Room 208
`Miami, Florida 33175-2474
`T (786) 315-2590 F (786) 315-2599
`www_miamidade.go~/building
`
`SCOPE:
`This NOA is being issued under the applicable rules and regulations governing the use of construction
`materials. The documentation submitted has been reviewed by Miami-Dade County Product Control
`Section and accepted by the Board ofRui~s and Appeals (BORA) to be used in Miami Dade County and
`other areas where allowed by the Authority Having Jurisdiction (AHJ).
`
`This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product
`Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County)
`reserve the right to have this product or material tested for quality assurance purposes. If this product or
`material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing
`and the AHJ may immediately revoke, modifY, or suspend the use of such product or material within
`their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami-Dade
`County Product Contr()l Section that this product or material fails to meet the requirements of the
`applicable building code."
`
`This product is approved as described herein, and has been designed to comply with the Florida Building
`Code and the High Velocity Hurricane Zone of the Florida Building Code.
`,
`
`'
`
`DESCRIPTION: FAST FELT®
`
`LABELING: Each unit shall bear a permanent label with the manufacturerts name or logo, city, state
`and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted
`herein.
`
`I
`
`RENEWAL of this NOA shall be considered after a renewal application has been filed and there has
`been no change in the applicable building code negatively affecting the performance of this product.
`TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
`change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an
`endorsement of any product, for sales, advertising or any other purposes shall automatically terminate
`this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
`NOA,
`ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and
`followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
`displayed, then it shall be done in its entirety.
`INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
`distributors and shall be available for inspection at thejob site at the request of the Building Official.
`
`
`This NOA revises NOA No. 08-0118.17 and consists of pages 1 thr\jYugh4.
`The submitted documentation was reviewed by Jorge L. Acebo.
`,
`
`, (j~~
`
`( \
`
`, '
`
`NOA No.: 10-1118.03
`Expiration Date: 01/15/14
`Approval Date: 03/17/11
`Page 1 of 4
`
`
`
`ROOFING COMPONENT APPROVAL
`
`Catee;ory:
`Sub-Category:
`Material:
`
`Roofing
`
`Underlayment
`
`Asphalt
`
`
`SCOPE:
`
`This acceptance is for FAST FELT®roofing underlayment as described in this Notice of Acceptance, for
`
`use with approved prepared roof assemblies where ASTM D226 Type II underlayment and tin caps are
`
`specified and installed with prescribed approved fasteners and fastener densities. (See limitations below.)
`
`
`PRODUCT DESCRIPTION:
`
`Product
`FASTFELT®
`
`Product
`Test
`Description
`Specification
`Dimensions
`36" x 72' rolls ASTM D 226 Asphalt Saturated Felt underlayment with
`Type II
`intergrated nylon fastening tabs.
`
`MANUFACTURING LOCATION:
`I. Houston, TX
`
`EVIDENCE SUBMITTED:
`Test Ageo'cy
`
`Underwriters Laboratori~s, Inc.
`PRl Construction Materials Technologies
`Exterior Research & Design, LLC
`
`Trinity IERD
`
`Test Identifier
`
`Test NamelReport
`
`Date
`
`02NK49693
`ATL-05 8-02-0 1
`#01460.06.03
`#01460.12.05
`L7770.09.07-I-RI
`L7770.01.08-2
`L 7770.01.08-1
`L7770.11.10
`
`UL790
`ASTMD226
`TAS 117
`
`01107/03
`10114/10
`06/26/03
`12/21105
`01107/08
`TAS 114-C
`TAS JI7-BI Dip Test 01107108
`Incline Test
`01107/08
`11115/10
`TAS 117-B
`
`APPROVED ASSEMBLIES:
`Deck Type 1:
`Wood, Non-insulated
`
`I
`
`Deck Description:
`
`19
`
`/ 32" or greater plywood or wood plank
`
`System E(l):
`
`Base sheet mechanically fastened TO deck.
`
`Base Sheet:
`
`One or m'ore plies of Fast Felt® with a minimum 4" side lap and a 6" end lap
`
`mechanically fastened to deck with approved nails at a spacing of 6" o.c. at the
`
`laps and two staggered rows 12" o.c. the field of the roll.
`
`
`Surfacing:
`
`Approved Roof assemblies.
`
`NOA No.: to-l11S.03
`Expiration Date: 01115/14
`Approval Date: 03117/11
`Page 2 of 4
`
`
`
`-----------------~------
`
`INSTALLATION REQUIREMENTS:
`1. All nail fasteners securing Fast Felt® to the roof deck shall be nailed through the center of the Fast
`Felt® Nylon fastening tab (W' maximum deviation) which is integrally attached to the Fast Felt®
`underlayment. See Detail "A".
`
`2. The flat underside of the head of each nail fastener securing Fast Felt® to the roof deck shall be
`driven flush to the surface of the Fast Felt® Nylon fastening tab.
`.
`
`3. Fast Felt® underlayment shall be installed in accordance with the applicable Roofing Application
`Standard that pertains to the approved roofing system in which it is used.
`
`Detail "A"
`
`FAST FELT® NAIL FASTENING PATTERN
`
`
`~4' OVERlAP
`
`..
`
`..
`•
`
`..
`..
`
`..
`
`•
`..
`
`~ FAST FELT (J)NYLON
`FASTENING TABS
`
`FAST FELT®
`UNOERlAYMENT
`
`NOA No.: 10-1118.03
`Expiration Date: 01115/14
`Approval Date: 03/17/11
`Page 3 of 4
`
`) '.
`
`
`
`GENERAL LIMITATIONS:
`I. Fire classification is not part of this acceptance.
`2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance
`with applicable building code. Fast Felt® underlayment shall be installed in strict compliance with
`applicable Building Code.
`3. Fast Felt® underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities.
`4. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels.
`Sweep the deck thoroughly to remove any dust and debris prior to application.
`S. Fast Felt® underlayment shall not be applied over an existing roof membrane as a recover system.
`6. Fast Felt® underlayment shall not be left exposed as a temporary roof for longer than 30 days of
`application.
`7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product
`with specific prepared roofing products. _
`8. Fast Felt® underlayment may be used with any approved roof covering Notice of Acceptance listing Fast
`Felt® underlayment as a component part of an assembly in the Notice of Acceptance.
`If Fast Felt®
`underlayment is not listed; a request may be made to the Authority Having Jurisdiction (AHJ) or the
`Miami-Dade County Product Control Department for approval provided that appropriate documentation is
`provided to detail compatibility of the products, wind uplift resistance, and fire testing results.
`9. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product
`Control Notice of Acceptance and applicable Building Code.
`10. All membranes or pay~aging shall bear the imprint or identifiable marking of the manufacturer's name or
`logo and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade
`County Product Control Seal as shown below.
`,~I!MIIJ!I'AMJ·;1·a@'i{'~rf'3?I!!JU'N'TY• •~
`
`END OF THIS ACCEPTANCE
`
`NOA No.: 10-1118.03
`Expiration Date: 01115114
`Approval Date: 03/17/11
`Page 40f 4
`
`