`Dosage Forms:
`
`Parenteral Medications
`
`Volume 2: Facility Design;
`Sterilization ond Processing
`
`John D. Ludwig
`
`, f
`Enigma
`
`Edited by
`
`Sandeep Nema
`
`Pufiw I. UL "IAIV
`
`Regeneron Exhibit 1016.001
`
`Regeneron Exhibit 1016.001
`
`
`
`Pharmaceutical Dosage
`Forms
`
`Regeneron Exhibit 1016.002
`
`
`
`This page intentionally left blank
`
`Regeneron Exhibit 1016.003
`
`
`
`Pharmaceutical Dosage
`Forms
`
`Parenteral Medications
`Third Edition
`
`Volume 2
`Facility Design, Sterilization and
`Processing
`
`Edited by
`
`Sandeep Nema
`Pfizer, Inc.
`Chesterfield, Missouri, U.S.A.
`
`John D. Ludwig
`Pfizer, Inc.
`Chesterfield, Missouri, U.S.A.
`
`informa
`
`healthcare
`
`Regeneron Exhibit 1016.004
`
`
`
`First published in 1984 by Marcel Dekker, Inc., New York, New York.
`This edition published in 2010 by lnforma Healthcare, Telephone House, 69 77 Paul Street, London EC2A
`4LQ, UK.
`
`Simultaneously published in the USA by lnforma Healthcare, 52 Vanderbilt Avenue, 7th Floor, New York,
`NY 10017, USA
`
`Inforn1a Healthcare is a trading division of lnforma UK Ltd. Registered Office: 37 41 Mortimer Street,
`London WlT 3JH, UK. Registered in England and Wales number 1072954.
`
`:i.:;2010 l nforn1a Healthcare, except as otherwise indicated
`
`No claim to original U.S. Government works
`
`Reprinted material is quoted with permission. Although every effort has been made to ensure that all
`owners of copyright material have been acknowledged in this publication, we would be glad to
`acknowledge in subsequent reprints or editions any omissions brought to our attention.
`
`All rights reserved. No part of this pubUcation may be reproduced, stored in a retri.eval system, or
`transmitted, in any form or by any means, electronic, mecbanicaJ, photocopying, recording, or otherwise,
`unless with the prior written permission of the publisher or in accordance with the provisions of the
`Copyright, Designs and Patents Act 1988 or tmder the terms of any licence permitting limited copying
`issued by the Copyright Licensing Agency, 90 Tottenham Court Road, London WlP OLP, UK, or the
`Copyright Clearance Center, Inc., 222 Rosewood Drive, Danvers, MA 01923, USA (http://www.
`copyright.com/ or telephone 978 750 8400).
`
`Product or corporate names may be trademarks or registered trademarks, and are used only for
`identification and explanation without intent to infringe.
`
`This book contains information from reputable sources and although reasonable efforts have been made
`to publish accurate information, the publisher makes no warranties (either express or implied) as to the
`accurncy or fitness for a particular purpose of the information or advice contained herein. The publisher
`wishes to make it clear that any views or opinions expressed in this book by individual authors or
`contributors are their personal views and opinions and do not necessarily reflect the views/opinions of
`the publisher. Any information or guidance contained in this book is intended for use solely by medical
`professionals strictly as a supplement to the medical professional's own judgement, knowledge of the
`patient's medical history, relevant manufacturer's instructions and the appropriate best practice
`guidelines. Because of the rapid advances in m.edical science, any information or advice on dosages,
`procedures, or di.agnoses should be independently verified. Thi.s book does not indicate whether a
`particular treatment is appropriate or suitable for a particular iJ1dividual. Ultimately it is the sole
`responsibiJity of the medical professional to make h.is or her own professional judgements, so as
`appropriately to advise and treat patients. Save for death or personal injury caused by the publisher's
`negligence and to the fullest extent otherwise permitted by law, neither the publisher nor any person
`engaged or employed by the publisher shall be responsible or liable fo,, any loss, inju1y or damage caused
`to any person or property arising in any way from the use of this book.
`
`A CfP record for this book is available from the British Library.
`
`Library of Congress C.itilloging iJ\ Public.ition Dat.i .ivaifoble on .ipplic.ition
`
`ISBN 13: 9781420086454
`ISBN 13: 9781420086539 (three volume set)
`
`Orders may be sent to: Informa Healthcare, Sheepen Place, Colchester, Essex C03 3LP, U.K
`Telephone: +44 (0)20 7017 5540
`Email: CSDhealthcarebooks@informa.com
`Website: http://informahealthcarebooks.com/
`
`For corporate sales please contact: CorporateBooksIHC@informa.com
`For foreign rights ple.ise cont.,ct: RightsIHC@informa.com
`For reprint permfasions please contact PermissionsIJ-IC@informa.com
`
`Typeset by MPS Limited, A Macmillan Company
`Printed and hound in lndia
`
`Regeneron Exhibit 1016.005
`
`
`
`We dedicate this work to those who have inspired us.
`To 1ny parents Walter and Ruth Ludwig and my wife Sue Ludwig
`To my parents Hari and Pratibha Nema and my wife Tina Busch Nema
`
`Regeneron Exhibit 1016.006
`
`
`
`This page intentionally left blank
`
`Regeneron Exhibit 1016.007
`
`
`
`Foreword
`
`I was a faculty member 11t the University of Tennessee 11nd 11 colle11g1.1e of Dr. Kenneth Avis
`when he conceived, org11nized, 11nd edited (along with HA. Lieberm11n and L. Lachman) the
`first edition of this book series that was published in 1984. lt was so well received by the
`pharmaceutic11I science community th11t an expanded three-volume second edition w11s
`published in 1.992. Dr. Avis did not smvive long enough to oversee a third edition, and it was
`questionable whether a third edition would ever be published until two of his gradttate
`students, Ors. Nemil and Ludwig, took it upon themselves to Ci\rry on Dr. Avis' trndition.
`Their oversight of this third edition is work that their mentor would be highly pleased
`ond proud of. From 29 diapters in the second edition to 43 diopters in this new edition, th.is
`three-volume series comprehensively covers both the traditional subjects in p11renteral science
`and technology as well 11s new and expanded subjects. For example, separate chapter topics in
`this edition not found in previous editions include solubility and solubilization, depot delivery
`systems, biophysical and biochemic11l characterization of peptides 11nd proteins, container(cid:173)
`closure integrity testing, woter systems, endotoxin testing, focused ch11pters on different
`sterilization methods, risk assessment in 11septic processing, viStlill inspection, 11dvances in
`injection devices, RNAi delive.ry, regulatory considerations for excipie11ts, techniques to
`evaluate pain on injection, produ ct specificotions, extractables mid leachables, process
`analytical technology, and quality by design.
`The editors h11ve done an outst11nding job of convincing so m11ny top experts in their
`fields to author these 43 chapters. The excellent reputations of the 11uthors and editors of this
`book will guarantee superb content of each d1apter. There is no other book in the world that
`covers the breadth 11nd depth of p11renteral science 11nd technology better than this one. In my
`opinion, the editors have achieved. their primary objectives publishing a book that contains
`current and emerging sterile product development and manufacturing information, and
`maintaining the high standard of quaJity that readers would expect.
`
`Michael J. Akers
`Baxfe,- BioPlwrma Solutions
`Bloo111i11gfon, Indiana, U.S.A.
`
`Regeneron Exhibit 1016.008
`
`
`
`This page intentionally left blank
`
`Regeneron Exhibit 1016.009
`
`
`
`Preface
`
`Pharmaceutical Dosage Forms: Parenteral Medicatio11s was originally published in 1984 and
`immediately accepted as a definitive reference in academic institutions and the pharmaceutical
`industry. The second edition was published in 1993. The ensuing years have produced
`incredible technological adwmcement. Classic small-molecule drugs are now complemented
`by complex. molecules such as monoclonal antibodies, antibody fnigroents, aptamers,
`antisense, RN Ai therapeutics, and Di A vaccines. There have been significant in11ovations in
`delivery devices, analytical techniques, in-s.ilico modeling, and manufacturing and control
`technologies. ln addition, the global regttlatory environment has sl1ifted towa.rd greater
`emphasis on science-based risk assessment as evidenced by the evolvillg cGMPs, quality by
`design (QbD), process analytical technology (PAT), continuous processing, real time release,
`and other initiatives. The rapidly changing landscape in the parenteral field was the primary
`reason we undertook the challenging task of updating the three volumes. Our objectives were
`to (i) revise the text with current and emerging sterile product development and
`manufacturiug science and (ii) maintain the high standard of quality the readers expect.
`The third edition 11ot only reflects enhanced content in all the chapters, but also more
`th,m half of the chapters are new 11t1derscoring the rapidly advancing technology. We have
`divided the volumes into logical subunits volume 1 addresses formulation ru1d p11ckaging
`aspects; voltune 2, facility design, sterilization and processing; and volume 3, regulations,
`validation and future directions. The authors invited to contribute chapters are established
`leaders with proven track records in their specialty areas. Hence, the textbook is authoritative
`and contains much of the collective experience gained in the (bio)pharmaceutical industry over
`the last two decades. We are deeply grateful to all the authors w/10 made this work possible.
`Volmne l begins with a bjstorical perspective of injectable dmg therapy and common
`routes of administration. Fonnulation of small molecules and large molecules is presented in
`depth, indudi11 g ophthalmic dosage fonns. Parenteral packaging options are discussed
`relative to glass and plastic containers, as well as elastomeric closures. A definitive chapter is
`provided on container clostu-e integrity.
`Volume 2 presents chapters on facility design, cleanroom operations, and control of the
`environment. A chapter discussing pharmaceutical water systems is included. Key quality
`attributes of sterile dosage forms are discussed, including particulate matter, endotoxin, and
`sterility testing. The most widely used sterilization techniques as well as processing
`technologies are presented. Volume 2 concludes with a11 in-depth chapter on lyophiJjzation.
`Volume 3 fornses on regulatory requirements, risk-based process design, specifications,
`QbD, and extractables/leachables. In addHion, we have included chapters on pare11teral
`administration devices, siRNA delivery systems, injection site pain assessment, and control,
`PAT, and rapid microbiology test methods. Volume 3 concludes with a forward-looking
`chapter discussing the future of parenteral product manufacturing.
`These three volumes differ from other textbooks in that they provide a learned review on
`developing parenteral dosage forms for both small molecules and biologics. Practical guidance
`is provided, in iiddition to theoretical iispects, for how to bring a drug candidiite forward from
`discovery, through preclinical and clinical development, manufacturing, validation, and
`eventual registration.
`The editors wish to thaJ1k Judy Cfarkston and Lynn O'Toole-Bird (Pfizer, lnc.) for their
`invalnable assistance and organizational support during this project, and Sherri Niziolek and
`Bianca Turnbull (lnforma Healthcare) for patiently leading us through the publishing process.
`
`Regeneron Exhibit 1016.010
`
`
`
`X
`
`PREFACE
`
`We also acknowledge the assistance of Pfizer, Inc. colleagues Lin Chen and Min Huang for
`reviewing several of the chapters.
`We would like to expre~ special gratitude to the late Kenneth E. Avis (University of
`Tennessee College of Phannacy) for his dedication to teaching and sharing practical
`knowledge in the area of parenteral medications to so many students over the years,
`including us. Finally, we acknowledge the contributions of Dr Avis, Leon Lachman, and
`Herbert A. Lieberm,m who edited the earlier editions of this book series.
`
`Sandeep Nema
`John D. Ludwig
`
`Regeneron Exhibit 1016.011
`
`
`
`Contents
`
`Fore-..vord M ichael J. Akers
`P,·eface
`ix
`Contributors
`
`xiii
`
`vii
`
`J. Aseptic manufacturing facility design
`l
`Ma rk Caldwell, Bob Helt, Bef/J Holden, Fra11cesca McBride, and Kevin Schreier
`
`2. Personnel and their impact on clean room operations
`Jea,me Moldeu/muer
`
`56
`
`3. Th e fun d amentals of an environmental control program
`William H. Miele
`
`80
`
`4. Water systems for parenteral facilities
`Joseph f. Manfredi
`
`91
`
`5.
`
`·rarticulate matter: subvisible
`D. Scoff Aldrich
`
`114
`
`6. Endotoxin testing
`Michael £. Dawson
`
`146
`
`7. The compendia! sterility tests
`Scott V. W. Sutton
`
`187
`
`8. Industrial sterilization technologies: principles and overview
`A1111e F. Boofh
`
`195
`
`9. Steam sterilization
`Ja111e Agalloco
`
`221
`
`10. Gas, vapor, and liquid chemical sterilization
`James Agalloco
`
`241
`
`11. Dry heat depyrogenation and sterilization
`Debora// Havlik and Kevin Trupp
`
`255
`
`268
`12. Radiation sterilization
`Bany P. Faira 11d a11d Dusa11 Razem
`
`Regeneron Exhibit 1016.012
`
`
`
`xii
`
`CONTENTS
`
`297
`13. Filters and filtration
`Maik W. Jornit: and Theodore H. Meltzer
`
`334
`14. Processing of small volume parenterals and large volume parenterals
`Donald A Eisenhauer, Roland Schmidt, Christine Martin, and Steven G. Schultz
`
`15. Freeze-drying: principles and practice
`Steven L. Nail and Larry A. Gatlin
`
`353
`
`Tndex
`
`.38.3
`
`Regeneron Exhibit 1016.013
`
`
`
`Contributors
`
`James Aga11oco Agalloco & Associates, Belle Mead, New Jersey, U.S.A.
`
`D. Scott Aldrich Ultramikro, LLC, Richland, Michigan, U.S.A.
`
`Anne F. Booth Booth Scientific, Inc., Hendersonville, North C<1rolina, U.S.A.
`
`Mark Caldwell Jacobs Engineering Group, Inc., Conshohocken, Pennsylvania,
`U.S.A.
`
`Michael E. Dawson Associates of Cape Cod, Inc., Falmouth, Massachusetts, U.S.A.
`
`Donald A. Eisenhauer Abbott Laboratories, North Chiciigo, Illinois, U.S.A.
`
`Barry P. fairand Sterigenics International, Dublin, Ohio, U.S.A.
`
`Larry A. Gatlin PK, LLC, Groton, Connecticut, U.S.A.
`
`Deborah Havlik R&D ·Microbiology, Hospirn, Inc., Lake Forest, fl1inois, U.S.A.
`
`Bob Helt Jacobs Engineering Group, Inc., Conshohocken, Pennsylvania, U.S.A.
`
`Beth Holden Jacobs Engineering Group, Inc., Conshohocken, Pennsylvania, U.S.A.
`
`Maik W. Jornitz Sartorius Stedim North America, Inc., Bohemia, New York, U.S.A.
`
`Joseph J. Manfredi GMP Systems, [nc., Fairfield, New Jersey, U.S.A.
`
`Christine Martin Abbott GmbH & Co. KG, Ludwigshafen, Germany
`
`Francesca McBride Jacobs Engineering Group, Inc., Conshohocken, Pennsylvania, U.S.A.
`
`Theodore H. Meltzer Capitola Consultancy, Bethesda, Maryland, U.S.A.
`
`WilJiam H. Miele Pfizer Global M1mufacturing, Kalamazoo, Michigan, U.S.A.
`
`Jeanne Moldenhauer Excellent Pharma Consulting, Mundelein, Dlinois, US.A.
`
`Steven L.
`
`ail Baxter Pharmaceutical Solutions, Bloomington, fndiana, U.S.A.
`
`Dusan Razem Ruder Boskovic Institute, Zagreb, Croatia
`
`Roland Schmidt Abbott GmbH & Co. KG, Ludwigshafen, Germany
`
`Kevin Schreier Jacobs Engineering Group, Inc., Conshohocken, Pennsylvania, U.S.A.
`
`Regeneron Exhibit 1016.014
`
`
`
`xiv
`
`CONTRIBUTORS
`
`Steven G. Schultz Abbott Laborntories, North Chicago, Illinois, U.S.A.
`
`Scott V. W. Sutton Microbiology Network, Inc., Rochester, New York, U.S.A.
`
`Kevin Trupp Global Sterilization Engineering, Hospira, Inc., Lake Forest, Illinois, U.S.A.
`
`Regeneron Exhibit 1016.015
`
`
`
`11 Aseptic manufacturing facility design
`
`Mark Caldwell, Bob Helt, Beth Holden, Francesca McBride, and Kevin Schreier
`
`INTRODUCTION
`Sterile products may be in liquid or powder form (among others) as drug products and may be
`presented in formats including ampoules, vials, p refilled syringes, presterilized bottles, and
`blow-fill-seal containers. Product form and presentation i11fluence processb1g conditions,
`equipment selection, and therefore, facility design. The sterile envelope refers to all the steps
`carried out du.ring and following the final sterile filtration step tllrough process completion,
`which occurs after filled product containers are sealed and a risk of environmental
`contamination to tlle product is eliminated. These steps include:
`
`• Adjuvant, buffer and media formulation
`• Addition of excipients
`• Adjustment of concentration to achieve target potency
`• Sterile filtration
`• Component preparation
`• Filling, stoppering/plugging, and sealing of product in final dosage containers
`
`The design of the facility must meet all applicable regulatory guidelines, and meet GMP
`and safety guidelines. Current Good Manufacturing Practice (GMP) requires that areas of
`operation used for aseptic processing must prevent contamination from particles and microbes
`that may be present in the air, on product contact surfaces, or shed from personnel (1 5).
`When processing biological products, such as live virus vaccines, attenuated vaccines
`and viral vectors, the biohazard nature of these products place extra demands on the facility.
`Potent compounds, like some biological products, also pose a risk to the operator and
`environment. Therefore, the facility and process design must also ensure both product and
`persom,el safety.
`This chapter establishes a basis for compliance with the global regulatory expectations
`for facility design, equipment interfaces, and utility requirements applicable to sterile
`processing and the manufacture of sterile products (6 10).
`
`FACILITY DESIGN DRIVERS
`As each facility is being designed, process requirements specific to each product must be
`considered. Each different type of product has different facility needs. Also, the number of
`products to be manufactured and tlle production campaign strategy will impact the facility
`design.
`
`Product Types
`Chemical Bulk Drug Substances (AP])
`Sterile chemical bulk dmg substances are derived from chemical reactions. Facilities producing
`sterile API will be required to provide protection of the product during syntllesis, isolation,
`and bulk filling. An adjuvant produced by precipitation is an example of a sterile APL
`
`Pofe1tt Compo111tds
`Potent compounds are classified as those chemical drug substances that are considered to be
`toxic to humans when exposure limits are exceeded, and may cause allergic reactions, birth
`defects, cancer, or other conditions. For this reason, it is required to ensure protection of
`operators working with potent compounds, ensure containment of all operations, and
`prevent release of products into the environment. It is acceptable to permit production of
`potent compounds in nrnltiproduct facilities, provided the suite is segregated from other
`operations.
`
`Regeneron Exhibit 1016.016
`
`
`
`2
`
`VOLUME 2: FACIU7Y DESIGN, STERILIZATION AND PROCESSING
`
`Following filling, it is recommended to wash the exterior of vials produced in potent
`compound facilities to limit uncontrolled exposure to the product during downstream
`operations.
`
`Antibiotics
`Antibiotics are drugs produced to treat bacterial or fungal infections. Antibiotics are considered
`to be sensitizers and can generate mild to severe allergic reactions in patients and operators. It is
`required to segregate production operations from personnel outside the production area.
`Campaigns of antibiotic must be segregated from other products, as the potential for cross(cid:173)
`contamination between products can occur. In addition, (3-lactam (penicillin) and nonpenicillin
`based (cephalosporin) antibiotic prodttcts are not permitted to be prodtlced in the same facility,
`as there is evidence that intolerance can occur for one antibiotic type, and not another.
`To accomplish this segregation, it is a requirement that a separate dedicated Sttite be
`constructed for each antibiotic family. This suite can be housed inside a common strncture
`with other functions. At no time should antibiotic production personnel come into contact with
`personnel operating in media or fermentation areas while gowned.
`Following filling, it is recommended to wash the exterior of vials produced in antibiotic
`facilities to limit uncontrolled exposure to the product during downstream operations.
`
`Biological Product
`This category includes therapeutic proteins generated by fermentation or cell culture and
`inactivated vaccines. The facility is to be designed in same way as API production, except that
`terminal sterilization is often not feasible, due to the fragility of the product.
`
`Live Vi ms Vaccines
`Vaccines containing a live virtts, or viral vector, must be designed to provide containment of
`the organism to protect both operators and the environment. Viral vectors are virus-like
`particles that inject genetic material into the cells of the organism being treated and are treated
`in a similar manner to live viruses. The biosafety level designated for the organism will drive
`decisions regarding the level of environmental controls that is required for the facility.
`Typically, these products require the use of adjuvants and will be suspension products,
`incapable of being filter sterilized. Products cannot be terminally sterilized. Live virus vaccine
`products can be campaigned in a multiproduct facility, as long as the vaccine production area
`is segregated from the remainder of the facility. Following the completion of tJ1e Uve virus
`campaign, the suite will need to be completely decontaminated prior to ttse for anoU1er
`product.
`
`Facility Types
`Single Product, Dedicated
`This facility is designed to produce a single product at any one time, throughout the year,
`without concern for cross-contamination with a second product. The facility can be operated to
`produce nmltiple products in a series of campaigns, converting between products.
`
`Multiproduct M11ltis11ite
`This facility is designed to produce mttltiple products simultaneously in multiple sterile suites.
`Sterile operations in each suite are to be segregated from one another to ensure that cross(cid:173)
`contamination is prevented. It is a recommendation to clean and decontaminate any used
`components or equipment prior to exiting the suite and entering the return corridor.
`
`Production Area Description
`Co11ve11tio11al Aseptic Techllology: Open
`111 conventional aseptic processing, the product is exposed to the room environment during
`operation. For this reason, aseptic operations are required to be performed tmder ISO 5
`
`Regeneron Exhibit 1016.017
`
`
`
`ASEPTIC MANUFACTURING FACILITY DESIGN
`
`3
`
`conditions, by sufficiently gowned operators, trained in aseptic technique. Sterility assurance
`levels for aseptic operations, including filling of vials or syringes, can be maximized through
`the use of barriers such as restricted access barrier systems or isolators to limit the size of the
`aseptic environment and remove operators from the ISO 5 fill area.
`
`Terminally Sterilized Product
`Whenever possible, it is required to terminally sterilize filled units of product. Application of
`an "overkill" sterilization methodology can provide a sterility assurance level of 10- 6, or better.
`Sterilization can be by steam, dry heat, gas, or radiation.
`
`Restricted Access Barrier: Ope11 and Closed
`As defined by ISPE: A restricted access barrier system (RABS) is an advanced aseptic
`processiJ1g system that can be utilized in many applications in a fill-finish area. RABS provides
`an enclosed environment to reduce the risk of contamination to product, containers, closures,
`and product contact surfaces compared to the risks associated with conventional cleru1
`room operations. RABS can operate as "doors closed" for processing with very low risk of
`contamination similar to isolators, or permit rare "open door interventions" provided
`appropriate measures are taken (11).
`In representative installations recently constructed, there is a wide variety of equipment
`configurations referred to as RABSs. In constniction detail, some approximate isolators in their
`level of segregation of the clean environment from the background environment, while other
`examples employ less rigorous segregation between the dean environment and the
`background room.
`When barrier doors are required to be opened, the opening must be protected within an
`ISO 5 zone, to the extent necessary to ensure continuous ISO 5 coverage. The door mttst be
`permitted to be opened without leaving the ISO 5 zone.
`
`I sola fio11 Tecl111ology
`As defined by ISPE: An isolator is a leak-tight enclosure designed to protect operators from
`hazardous/potent processes or protect processes from people or detrimental external environ(cid:173)
`ments or both. A basic enclosure consists of a shell, viewing window, glove/sleeve assemblies,
`supply and exhaust filters, light (s), gauge (s), input and output openings (equjpment door
`airlocks, RTPs, etc.), and various other penetrations. There are two types of isolators:
`
`Closed isolators. Isolators operated as closed systems do not exchange unfiltered rur or
`contaminants with adjacent environments. Their ability to operate without personnel access to
`the critical zone makes isolators capable of levels of separation between the internal and
`external environment unattainable with other technologies. Because the effectiveness of this
`separation, dosed isolators are ideally suited for application in the preparation of sterile
`and/or toxic material. Aseptic and containment isolators are two types of closed isolators.
`
`Open isolators. Open isolators differ from closed isolators in that they are designed to allow
`for the continuous or semicontinuous egress of materials during operation while maintaining a
`level of protection over the internal environment. Open isolators are decontaminated while
`closed, and then opened duru1g manufacturing. Open isolators typically are used for the
`aseptic filling of finished pharmaceuticals (11).
`
`Closed Processiug
`Closed system sterile processing. A closed system is one that does not contain any open
`aseptic manipulations or interventions by design or operation and does not allow microbial
`ingress. Validated sterilization cycles must be provided. The product is separated from the
`surrounding room environment by a sterilizing grade vent filters. Leak testing must occur pr-e(cid:173)
`irnd post use to demonstrate the !>-ystem integrity.
`
`Regeneron Exhibit 1016.018
`
`
`
`4
`
`VOLUME 2: FACIU1Y DESIGN, STERJUZAT/ON AND PROCESSING
`
`EQUIPMENT AND PROCESS SYSTEM IMPACT ON FACILITY
`Jt is important to start the facility design with an understanding of eacb process step involved
`with the manufacture of a sterile product. 1n this section, an overview is provided for some of
`the more common process steps, including a description of the major equipment, material
`flows, and facility impacts.
`
`Nonactive Materials
`Nonactive materials are transported from the warehouse to the weigh/dispense area, where
`they are dispensed into contai11ers tmder a hood with high efficiency particulate air (HEPA)
`filtration. The hoods used in the dispensing operation shall be designed for protection of the
`product and may also need to protect the operator from exposme to potentially hazardous
`materials used in the formulation process.
`The number of hoods, and type, will be determined by evaluating the mtmber of
`weighing operations that must be performed, the size of the weighing operations, the
`compatibility of materials that must be weighed, and any special ergonomic or personnel
`safety concerns. Materials that are not compatible may need to be dispensed in separate hoods
`to prevent any cross-contamination concerns. Also, dispensing operations involving large bulk
`containers will require either a lift assist or pallet jack access to prevent operator injury,
`requiring the hood to be designed as a walk-in type.
`Hoods being designed for product protection typically recircttlate air back to the
`dispensing room to reduce the HV AC consumption for the area. However, when weighing
`hazardous materials, the air from the hood may need to be captured and exhausted to the roof
`through some type of environmental control device. Hoods of this type are typically designed
`to be negatively pressurized with respect to the dispensing room.
`Containers may be either single-use or reusable. Single-use containers are disposable.
`Reusable containers are required to be tracked and controlled to prevent cross-contamination
`of clean and used containers. Prior to reuse, used containers should be brought to a parts
`preparation washroom for cleaning and then placed in controlled storage.
`Nonactive materials ru·e dispensed into bags or plastic bottles and can be placed into
`plastic bins as part of preassembled kits. Preweighed nonactive materials are stored as kits and
`staged until they are ready to be transferred to the formulation area. Identifying labels should
`be placed on the containers.
`It is typical to provide a local WFI drop feeding a sink in the weigh/dispense area, with
`WFT temperature controlled by a local WFI d.rop cooler. The WFJ drop is periodically flushed
`and sampled per SOP. WFl is used to prepare solutions of nonactive materials in bottles. This
`operation may be performed with equipment such as a laboratory agitator.
`Bench scales are used for dispensing of sma!Jer-scale materials. Floor scales are used for
`larger quantities. Balances and measuring equipment should be of an appropriate range and
`precision.
`
`Active Materials
`Receipt/Storage
`Active materials, API or drug substance (OS), may be received in a wide variety of container
`types, in either frozen or liquid form, or as a solid. Carefu I co11sideration should be given to the
`form and container type, since this affects the storage, transport, preparation, and handling of
`API. The following list is provided to indicate the diversity of some common examples.
`
`1. Frozen in cryovessels, ranging in size from 50 to 300 L
`2. Frozen in small containers, ra11ging in size from 1 to 20 L
`3. As liquid in small containers, ranging in size from <1 to 20 L
`4. As powder in canisters, ranging in size from < ] to 50 kg
`
`Weighing and dispensing can occur for either sterile or 11onsterile material.
`It is recommended that sterile material be dispensed in an isolator to prevent
`contamination. The isolator should be fitted with a rapid decon antechamber to facilitate the
`addition of product and containers to be dispensed.
`
`Regeneron Exhibit 1016.019
`
`
`
`ASEPrlC MANUFACTURING FACILITY DESIGN
`
`5
`
`LJ!:CZHD
`
`UNLOAD &CLEAN
`EQUIPMENT STAGE
`
`MECIWUC..U.
`
`COil'ONENT PREP
`
`r~=-:::=.,
`
`MECHANJCAL
`
`;
`
`•
`
`D •so•
`C]IS07
`.,sou
`og=:No•-
`C :J !.::•.:-
`
`CJNonolUalllod
`
`!SOI
`
`EQUIPMENT
`WASH
`
`EQUIPMENT
`WASH
`
`EQUIPKHTWASH i COMPONENT PRi!'
`CCNV£NTIQNALi RABli OflERATIOtl5
`
`EQUIPMD/f WAiHICOMPON&NTPREP
`l50lATOR TfCNHOLDGY Ol'ERATKlN5
`
`Figure 1
`
`(See color insert) Weigh and dispense.
`
`onsterile material should he protected by HEPA filtration during dispensing operations
`to prevent addition of particulate.
`Containers of API should not be opened for sampling prior to use in the formulation
`area. Therefore, it is recommended that all lot of API containers be received at the warehouse
`facility with a tag-along container of sample volume, or with a material certificate of analysis
`from the supplier.
`If there are any concerns regardLng the cumulative time out of refrigeration for an API
`container, it should not be removed from cold storage in the warehouse c1rea until it is required
`for use (Fig. 1).
`
`Cryovessels
`For transporting lc1rge volumes of bulk API, cryovessels c1re preferred over small contc1iners.
`However, in c1ddition to the c1dded cost of the cryovessels, speciill considerntion should be
`given to their storc1ge c1nd trnnsport. Cryovessels can weigh approximately 1000 kg, before
`being filled with product. For this reason, it is recommended to avoid lifting them onto rnck
`storage. This may impact the size of the storage space, depending on the quantity of material to
`be stored. This space can be either located within a walk-in freezer or i11 a specic1l area
`equipped with a heat transfer system and ample docking stations for the required mun ber of
`cryovessels.
`It is recommended that cryovessels have wheels for portability and ease of movement,
`although moving them by band would prove difficult. For long distances, such as transport
`from warehouse storage, fork trucks should be used. Once inside the formulation area, a tank
`manipulator can be used, which allows the cryovessel to be pulled or pushed into position.
`Used cryovessels need to be cleaned prior to being returned to the supplier. This requires
`a designc1te