`Beyond Tried.
`True.
`
`
`
`
`
`
`GuideLiner® V3 Catheter
`
`Guide Extension Catheter With Half-Pipe Technology
`
` 1FEIEFIEX®
`
`Page 1
`
`VSIMDT00003665
`
`Teleflex Ex. 2164
`
`Medtronic v. Teleflex
`
`
`Page 1
`
`Teleflex Ex. 2164
`Medtronic v. Teleflex
`
`
`
`Beyond Tried. True.
`In 2009, the GuideLiner® Catheter revolutionized the concept of guide extension, creating new
`possibilities in interventional cardiology. Now in its third generation, the GuideLiner® V3 Catheter
`continues to build on a history of innovation and performance—one that's been demonstrated with
`more than half a million catheters in cath labs around the world.1
`
`”The GuideLiner gives me the
`
`confidence to deliver my chosen
`
`balloon or stem to almost any
`location.“
`
`—l\-111C"Ilc%é‘l‘v
`
`let“ Ml],
`
`I Art; lfnL'AI
`
`"The GuideLiner has become an
`
`indispensable part of my tool kit
`
`for complex PCI. Simply put, it's
`a game changer."
`lvlf-xithew Price, M II, Wu C, Ht AI
`
`2 These statements reflect the personal experience and opinion
`ofthe physician.
`
`Multiple Clinical Uses
`
`
`
`
`
`Coaxial alignment
`and backup support
`
`Deep-seating for distal
`device delivery
`
`Selective delivery
`of contrast
`
`1 Data on file.
`
`Page 2
`
`VSIMDTOOOOSGBB
`
`Teleflex Ex. 2164
`
`Medtronic v. Teleflex
`
`
`Page 2
`
`Teleflex Ex. 2164
`Medtronic v. Teleflex
`
`
`
`Designed to Perform
`
`It's notjust the proprietary half-pipe technology that sets the GuideLiner® V3 Catheter apart.
`The coil-reinforced extension is specifically designed to enable dependable deep-seating
`
`for the delivery of interventional devices to distal locations.
`
`Collar
`transition
`
`7
`
`Half-pipe
`
`
`channel
`
`
`Half—Pipe Technology
`
`
`
`
`
`The half-pipe Channel is designed to minimize
`device/collar interaction by directing and aligning
`devices through the collar transition, facilitating
`smooth device entry and seamless delivery.
`
`Half a Million
`
`Catheters.
`
`0 Reported Collar
`Separations in PCI.3
`
`The half-pipe construction is also
`designed to minimize the opportunity
`for device separation by creating a
`17 cm polymer bond between the
`extension and push rod.
`
`3 Based upon a reView of all device experience reports for coronary usage of
`GuldeLlneré V3 Catheters from launch through February 13‘ 2018. Data on file.
`
`Page 3
`
`VSlMDT00003667
`
`Teleflex Ex. 2164
`
`Medtronic v. Teleflex
`
`
`Page 3
`
`Teleflex Ex. 2164
`Medtronic v. Teleflex
`
`
`
`Tortuosity Tested
`
`From challenging lesions to impossibly acute angles, percutaneous coronary interventions have
`grown more complex. Since being introduced, GuideLiner catheters have been recognized by
`
`interventionalists as essential tools for addressing difficult anatomies.
`
`Guide Extension
`
` Highly Flexible, Coil-Reinforced
`
`
`The GuideLiner?) V3 Catheter's coilereinforced guide extension provides excellent
`flexibility and kink resistance allowing delivery through tortuous vessels to reach ------------------
`the target area.
`
`Coilereinforced guide
`extension is designed to
`maintain luminal integrity
`
`Kink resistant4
`
`
`
`g"""""" Stainless steel push rod for
`'
`strength and kink resistance
`
`Proximal tab
`
`
`
`4 Data on file.
`
`3 """"""" Ribbon wire push rod height (6 Fr.) = 0.012"
`
`Page 4
`
`VSIMDT00003668
`
`Teleflex Ex. 2164
`
`Medtronic v. Teleflex
`
`
`Page 4
`
`Teleflex Ex. 2164
`Medtronic v. Teleflex
`
`
`
`GuideLiner® V3 Catheter Dimensions
` 150 cm
`
`
`17 cm Half-pipe|
` 25 cm Rapid exchange section
`108 cm Push rod
`
`
`
`
`i
`1
`2 mm
`4 mm
`Radiopaque
`Radiopaque marker
`marker
`
`‘.
`
`White positioning markers at 95 cm (single) 8105 cm (double)
`to assistin placementthrough the guide
`
`Rapid exchange
`collar transition
`
`Added Backup Support
`
`With as little as 5 mm of extension, bench testing has shown that the GuideLiner® V3 Catheter
`significantly increases the backup support of a 6 Fr. guide catheter.
`
`
`
`6 Fr. Guide
`
`6 Fr. GuideLiner 6 Fr. GuideLiner 6 Fr. GuideLiner
`6 Fr. GuideLiner
`
`
`
`5 mm 10 mm0 mm 15 mm
`
`7 Fr. Guide
`
`8 Fr. Guide
`
`200
`
`150
`
`100
`
`50
`
`0
`
`a:
`3’
`t”
`.
`E?(I)
`o.
`:5
`e(U
`CD
`<1)
`G)
`E
`a)
`
`oD
`
`3;
`
`Testing completed by Vascular Solutions, Inc. Data on file. Comparative data may not be indicative of clinical performance.
`
`Extension Distance
`
`GuideLiner“D V3 Catheter
`GuideLiner'D Catheters are intended to be used in conjunction with guide catheters to access discrete regions of the coronary and/or peripheral vasculature, and
`to facilitate placement of interventionai devices.
`PRODUCT
`RAPID EXCHANGE
`WORKING
`no.
`SIZE
`REQUlRED GUlDECATHETER|.D.
`PUSH ROD op. GUIDE EXTENSION l.D.
`TlP 0.1:.
`LENGTH
`LENGTH
`
`5569
`5 Fr.
`5 Fr. ID. 20056" (1.42 mm)
`0.010" (0 25 mm)
`0.046" (1.17 mm)
`4.0 Fr. (1.35 mm/ 0 053")
`25 cm
`150 cm
`
`5570
`5.5 Fr.
`6 Fr.
`|.D. 20.066" (1.68 mm)
`0.012" (0.30 mm)
`0.051" (1.30 mm)
`4.8 Fr. (1.60 mm/ 0.063")
`25 cm
`150 cm
`
`5571
`6 Fr.
`6 Fr.
`|.D.20.070" (1.78 mm)
`0.012" (0.30 mm)
`0.056" (1.42 mm)
`5.1 Fr. (1.70 mm/0.067“)
`25 cm
`150 cm
`
`5572
`7 Fr.
`7Fr.|.D.20.078" (1.98 mm)
`0.012" (0.30 mm)
`0.062" (1.57mm)
`5.7 Fr. (1.90 mm/0.075")
`25cm
`150 cm
`
`5573
`8 Fr.
`8Fr. |.D.20.088" (2.24 mm)
`0.012" (0.30 mm)
`0.071" (1.80 mm)
`6.5 Fr.(2.16mm/0.085")
`25 cm
`150 cm
`
`
`
`
`
`
`
`
`
`
`
`
`
`
`
`Packaged in quantities ot1 unit per box.
`
`Page 5
`
`VSIMDT00003669
`
`Teleflex Ex. 2164
`
`Medtronic v. Teleflex
`
`
`Page 5
`
`Teleflex Ex. 2164
`Medtronic v. Teleflex
`
`
`
`Teleflex is a global provider of medical technologies designed to improve the health and quality of people's lives. We apply
`purpose driven innovation — a relentless pursuit of identifying unmet Clinical needs —to benefit patients and healthcare
`providers. Our portfolio is diverse, with solutions in the fields of vascular and interventional access, surgical, anesthesia,
`cardiac care, urology, emergency medicine and respiratory care. Teleflex employees worldwide are united in the under?
`standing thatwhat we do every day makes a difference. For more information, please visit teleflex.com.
`
`Teleflex is the home ofArrowE', Deknatel‘a, Hudson RCIP, LMA’S‘, Pilling‘fl, Rusch’g‘, and Weck‘3‘7trusted brands united by a
`common sense of purpose.
`
`Corporate Office
`Phone +1 610 225 6800, 550 E. Swedesford Road, Suite 400, Wayne, PA 19087, USA
`
`Regional Offices
`United States: Phone +1 919 544 8000, Toll Free 866 246 6990, cs@teleflex.com, 3015 Carrington Mill Boulevard,
`Morrisville, NC 27560, USA
`
`Latin America: Phone +1 919 433 4999, |a.cs@teleflex,com, 3015 Carrington Mill Boulevard, Morrisville, NC 27560, USA
`
`International: Phone +353 (0)9 06 46 08 00, orders.intl@teleflex.com, Teleflex Medical Europe Ltd.,
`IDA Business and Technology Park, Dublin Road, Athlone, Co Westmeath, Ireland
`
`Australia 1300 360 226
`Austria +43 (0)1 402 47 72
`
`Belgium +32 (0)2 333 24 60
`Canada +1 (0)800 387 9699
`
`China (Shanghai) +86 (0)21 6163 0965
`China (Beijing) +86 (0)10 6418 5699
`Czech Republic +420 (0)495 759111
`France +33 (0)5 62 18 79 4O
`Germany +49 (0)7151 406 0
`Greece +30 210 67 77 717
`India +91 (0)44 2836 5040
`
`Italy +39 0362 58911
`Japan +81 (0)3 6632 3600
`
`Korea +82 2 536 7550
`Mexico +52 55 5002 3500
`
`Netherlands +31 (0)88 00 215 00
`New Zealand 0800 601 100
`
`Poland +48 22 4624032
`Portugal +351 22 541 90 85
`Singapore (SEA nonidirect sales countries) +65 6439 3000
`Slovak Republic +421 (0)3377 254 28
`South Africa +27 (0)11 807 4887
`Spain +34 918 300 451
`Switzerland +41 (0)31 818 40 90
`
`United Kingdom +44 (0)1494 53 27 61
`For more information, please visit teleflex.com.
`
`Please see the Instructions for Use for a complete listing of the indications, contraindications, warnings and precautions.
`CAUTION: Federal Law (U.S.A.) restricts this device to sale by or on the order of a physician.
`
`Teleflex, the Teleflex logo, Arrow, Deknatel, GuideLiner’), Hudson RCI, LMA, Pilling, Rusch, and Weck are trademarks or registered trademarks of Teleflex
`Incorporated or its affiliates, in the U.S. and/or other countries.
`
`Information in this material is not a substitute for the product lnstructions for Use. Not all products may be available in all countries. Please contactyour
`local representative. Revised: 02/2018.
`
`© 2018 Teleflex lncorporated. All rights reserved. MC-003856 Rev 0.1
`
`1FelefIEX®
`
`Page 6
`
`VSIMDT00003670
`
`Teleflex Ex. 2164
`
`Medtronic v. Teleflex
`
`
`Page 6
`
`Teleflex Ex. 2164
`Medtronic v. Teleflex
`
`