`V3 catheter
`
`5F Guide Extension Catheter
`
`Medtronic v. Teleflex
`
`MORE RADIAL,
`LESS RESTRICTIONS
`
`by Vascular
`
`VSIMDT00006441
`
`Teleflex Ex. 2162
`
`
`Page 1
`
`Teleflex Ex. 2162
`Medtronic v. Teleflex
`
`
`
`END-TO-END INNOVATION
`
`SUPPORTS THE RADIAL REACH
`
`3mm Stent Crossing Profiles
`
`STENT MODE! MANUFACTURER—1'AMETER
`
`lon™
`Boston Scientific
`3mm
`0.042"
`0.044"
`
`
`0.046" I.D. to Facilitate Select Device Delivery“
`
`0.043"
`0,043"
`3mm
`Abbott
`Xience Prime® LL
`True Su pport for Small Vessel Delivery
`
`ecem Mended “ordiveny in conjuction with “he 7 Gu deLi-e+
`
`cofe sro nut um catil.owitht-o SF SuJideLinen
`The 5F GuideLiner V3 catheter was designed specifically
`luticns, Ine, Bata anfle,
`
`to support 5F guide interventions and small vessel delivery.
`Its small crossing profile allows it to fit through any 5F guide
`catheter which means fewer guide catheter restrictions and
`
`PROMUSElement” Plus Boston Scientific
`3mm
`0.041"
`0.042"
`
`
`VeriFLEX”
`Boston Scientific
`3mm
`0.040"
`0.040"
`
`
`greater confidence during interventions. —
`
`Increases back-up support while allowing deep-
`seating for coaxial alignment, facilitation of distal
`.
`:
`device delivery and selective delivery of contrast
`=
`
`.
`
`a
`
`nce eee —
`alee
`.
`.
`Lowest crossing profile GuideLiner catheter
`for superior deliverability | 0.053" OD
`
`
`Page 2
`
`Teleflex Ex. 2162
`Medtronic v. Teleflex
`
`
`
`Tea
`
`V3 catheter
`
`GuideLiner catheters are intended to be used in conjunction with guide catheters to access discrete regions ofthe
`coronary and/or peripheral vasculature, and to facilitate placement of interventional devices.
`
`Model
`
`Size
`
`Packaged in quantities of 1 unit per box.
`
`Rapid Exchange
`on
`Required Guide
`CatheterI.D. a: Length
`5F LD. 20.056"
`0.046"
`(142mm)
`(1.17mm)
`
`Working Length
`
`GuideLiner V3 Dimensions
`
`Whitepositioning markers at 95cm (single) & 105cm (double)
`to assist in placement through the guide
`
`Radiopaque marker
`
`Radiopaque marker
`
`CO_LY
`>
`Ipsecliesles |
`[star ence)
`25cm rapid exchange section
`Pieanlpe
`Pee)
`2 Ee —_—V“—
`=m
`*
`temic
`
`Medtronic v. Teleflex
`
`Please see the Instructions for Use for a completelisting of the
`indications, contraindications, warnings and precautions.
`CAUTION:Federal Law (U.S.A.) restricts this device to sale by or on the
`eesaci npc
`GuideLiner is a registered trademark of Vascular Solutions,Inc.
`Xience Primeis a registered trademark of Abbott Cardiovascular
`Systems Inc. lon, PROMUS Element and VeriFLEX are trademarksof
`Boston Scientific ScimedInc.
`
`:
`Vascular Solutions, Inc.
`ayehi Selaoaeelilay etaal
`Minneapolis, Minnesota 55369 USA
`Customer Service:
`United States: 888.240.6001
`customerservice@vasc.com
`
`oe Sa}
`x
`
`©2016 Vascular Solutions, Inc. All rights reserved. ML3078 Rev. D 07/16
`
`Deereseett)
`
`VSIMDT00006443
`
`Teleflex Ex. 2162
`
`
`Page 3
`
`Teleflex Ex. 2162
`Medtronic v. Teleflex
`
`