`
`“The GuideLiner makes some
`impossible cases possible and
`difficult cases easier.”
`
`— Interventional Ca-dialogist
`
`*These statementsreflect the personal experience and
`opinion of the physician.
`
`MULTIPLE CLINICAL USES
`
`Medtronic v. Teleflex
`
`“The GuideLiner has made complex
`procedures mucheasier, allowing
`me to succeed more quickly with
`less struggle.”
`— Interventional Cardiologist
`
`Deep-seating for coaxial
`alignment & backup support
`
`Deep-seating for distal device
`delivery
`
`Deep-seating for selective
`delivery of contrast
`
`VSIMDT00020815
`
`Teleflex Ex. 2063
`
`
`Page 1
`
`Teleflex Ex. 2063
`Medtronic v. Teleflex
`
`
`
`Guidenpyer
`
`V3 catheter
`
`GuideLiner catheters are intended to be used in conjunction with guide catheters to
`access discrete regions of the coronary and/or peripheral vasculature, and to facilitate
`placementof interventional devices.
`
`
`
`Model
`
`5570
`
`5571
`
`5572
`
`Size
`
`5.5F
`
`6F
`
`7F
`
`8F
`5573
`*Packaged in quantities of 1 unit per box.
`
`Rapid Exchange Length
`
`GuideLiner V3 Ordering Specifications
`Required Guide
`Catheter| .D.
`6F|.D. 20.066"
`(168mm)
`6F|.D. 20.070"
`(1.78mm)
`7F |.D. 20.078"
`(198mm)
`8F |.D. 20.088"
`(224mm)
`
`GuideLiner|.D.
`0.051"
`(1.30mm)
`0.056"
`(1.42mm)
`0.062"
`(157mm)
`0.071"
`(80mm)
`
`25cm
`
`25cm
`
`25cm
`
`25cm
`
`Working Length
`
`150cm
`
`150cem
`
`150cm
`
`150cm
`
`GuideLiner V3 Dimensions
`
`eT
`
`nig
`
`White positioning markers at 95cm (single) & 105cm (double)
`to assist in placement through the guide
`
`150cm
`
`+
`+
`>
`
`25cm rapid exchangesection 108cm push rod
`”)"T7em half-pipe ,
`2mm
`
`.
`\7
`
`
`Radiopaque marker
`
`Radiopaque marker
`
`
`
`Rapid exchange
`collar transition
`
`
`Please see theInstructions for Use for a completelisting of the indications,
`contraindications, warnings and precautions.
`CAUTION:Federal Law (U.S.A.) restricts this device to sale by or on the order of
`a physician.
`GuideLineris a registered trademark of Vascular Solutions,Inc.
`€2013 Vascular Solutions,Inc. All rights reserved. ML2858 Rev, A 12/13
`
`
`
`ascular
`SOLUTIONS
`
`Vascular Solutions, Inc.
`6464 Sycamore Court North
`Minnesota 55369 USA
`Minneapolis,
`CustomerService:
`: 888.240.6001
`United States:
`International:
`(001) 763.656.4298
`customerservice@vasc.com
`WWW.Vvasc.com
`
`Page 2
`
`VSIMDT00020816
`
`Teleflex Ex. 2063
`
`Medtronic v. Teleflex
`
`
`Page 2
`
`Teleflex Ex. 2063
`Medtronic v. Teleflex
`
`
`
`
`
`
`
`
`
`Makes even the
`most difficult intervention
`
`A FAST AND
`
`SMOOTH RUN. Guidenpy=
`
`
`
`
`GUIDE Ex
`
`
`
`Page 3
`
`V3 catheter
`
`
`ON CATHETER
`
` E TECHNOLOGY
`
` WITH HAL F-PIP
`
`ENSI
`
`VSIMDT00020817
`
`Teleflex Ex. 2063
`
`Medtronic v. Teleflex
`
`
`Page 3
`
`Teleflex Ex. 2063
`Medtronic v. Teleflex
`
`
`
`END-TO-END INNOVATION
`
`V3 COLLAR TRANSITION
`
`V3 HALF-PIPE
`CHANNEL
`
`V3 HALF-PIPE
`TECHNOLOGY
`
`Revolutionary half-pipe design facilitates
`smooth device entry and seamlessdelivery.
`The GuideLiner V3 half-pipe minimizes
`device/collar interaction by directing and
`aligning devices through the
`collar transition.
`
`Nea
`
`VSIMDT00020818
`
`Page 4
`
`Teleflex Ex. 2063
`Medtronicv. Teleflex
`
`
`Page 4
`
`Teleflex Ex. 2063
`Medtronic v. Teleflex
`
`
`
`THAT HELPS SIMPLIFY CHALLEN
`
`ADDED BACKUP SUPPORT
`
`With aslittle as 5mm of extension, the GuideLiner greatly increases the backup
`support of a 6F guide catheter.
`
`Bench testing demonstrates the 6F GuideLiner substantially increases backup support
`compared to standard guide catheters.
`
`200
`
`150
`
`100
`
`50
`
`0
`
`6F Guide
`
`6F GuideLiner 6FGuideLiner 6FGuideLiner 6FGuideLiner
`Omm
`5mm
`10mm
`15mm
`
`7F Guide
`
`8F Guide
`
`
`
`
`
`
`
`AverageBackupSupport(gf)
`
`
`
`Testing completed by Vascular Solutions, Inc. Data onfile.
`
`Extension Distance
`
`
`
`AVAILABLE IN 4 SIZES:
`PROXIMAL TAB
`
`0.0F, 6F, 7F, 8F
`
`
`STAINLESS STEEL PUSH ROD
`for strength and kink resistance
`
`VSIMDT00020819
`
`Page 5
`
`Teleflex Ex. 2063
`Medtronicv. Teleflex
`
`
`Page 5
`
`Teleflex Ex. 2063
`Medtronic v. Teleflex
`
`
`
`GING INTERVENTIONS.
`
`HIGHLY FLEXIBLE, COIL
`REINFORCED GUIDE EXTENSION
`
`The GuideLiner’s coil reinforced guide extension
`provides excellent flexibility and kink resistance allowing
`delivery through tortuous vessels to reach the target area.
`
`
`
`COIL REINFORCED
`DESIGN MAINTAINS
`
`LUMINAL INTEGRITY
`
`WWMl
`
`OPTIMAL KINK
`RESISTANCE
`
`VSIMDT00020820
`
`Teleflex Ex. 2063
`Medtronicv. Teleflex
`
`Page 6
`
`
`Page 6
`
`Teleflex Ex. 2063
`Medtronic v. Teleflex
`
`