`Catheter
`
`Coaxial uide extension with
`9
`rapid exchange convenience
`
`6F
`.melme,
`
`_
`
`s
`
`,
`
`
`
`Flexible coaxial guide liner that allows guide extension into vessel for deep seating
`
`Simplified mother and child technique for use in challenging interventions
`
`Rapid exchange convenience
`
`Page 1
`
`% Vascular
`
`OLUTIONS
`
`VSIMDT00027342
`
`Teleflex Ex. 2061
`Medtronic v. Teleflex
`
`IPR2020-00131
`
`
`Page 1
`
`Teleflex Ex. 2061
`Medtronic v. Teleflex
`IPR2020-00131
`
`
`
`G ”Ida/[767' provides a rapid excha
`
`Catheter
`
`THE PROBLEM
`
`Guide catheters can back-out
`
`when resistance is met while
`
`advancing a catheter or wire in
`
`challenging interventions
`
`
`
`The GuideLiner is delivered through
`standard guide catheters, resulting in an
`inner diameter that is approximately one
`French size smaller than the guide catheter
`
`Page 2
`
`VSIMDT00027343
`
`Teleflex Ex. 2061
`Medtronic v. Teleflex
`
`IPR2020-00131
`
`
`Page 2
`
`Teleflex Ex. 2061
`Medtronic v. Teleflex
`IPR2020-00131
`
`
`
`ge guide extension for added back—up support
`
`back—up support
`
`THE SOLUTION
`
`The GuideLiner provides an
`extension of the guide for
`deep seating and added
`
`Delivery backbone
`
`
`6"-
`
`The GuideLiner is available in three sizes:
`® 5-in-6 (0.056" |.D.) — Model 5571
`
`6-in-7 (0.062" |.D.) — Model 5572
`
`7-in-8 (0.071" |.D.) — Model 5573
`
`length of devices used in the intervention
`
`allows deployment through the existing
`Y-adapter without limiting the effective
`
`The GuideLiner's rapid exchange design
`
`Page 3
`
`VSIMDT00027344
`
`Teleflex Ex. 2061
`Medtronic v. Teleflex
`
`IPR2020-00131
`
`
`Page 3
`
`Teleflex Ex. 2061
`Medtronic v. Teleflex
`IPR2020-00131
`
`
`
`interventional devices.
`
`”deli/76v
`
`Catheter
`
`The GuideLiner catheters are intended to be used in conjunction with
`guide catheters to access discreet regions ofthe coronary and/or peripheral
`vasculature, and to facilitate placement and exchange ofguidewires and other
`
`7.x
`
`r
`
`
`
`Gum-there.compatibility _—_l
`
`-l
`
`
`--l
`
`
`
`
`
`”Packaged in quantities ofi unit per box.
`”Available November 2009.
`
`20cm rapid exchange ,
`
`
`
`
`White positioning markers at 95cm (single) & 105cm (double)
`to assist in placement through the guide
`
`
`
`
`
`
`transition
`
`Rapid exchange
`
`
`
`510(k) Pending
`Not available for sale within the U.S.
`
`Please see the Instructions for Use for a complete listing of the
`indications, contraindications, warnings and precautions.
`CAUTION: Federal law (U.S.A.) restricts this device to sale by or
`on the order ofa physician.
`GuideLiner is a trademark ofVascuIar Solutions, Inc.
`
`©2009 Vascular Solutions, Inc. All rights reserved.
`ML2114 Rev. A 08/09
`
`Page 4
`
`
`
`Vascular Solutions, Inc.
`6464 Sycamore Court
`Minneapolis, Minnesota 55369 USA
`ascular USA Customer Service: 888.240.6001
`8 0 L U T l 0 N S WWW.vascularsolutionscom
`
`EEIIEE
`TheraGenesis GmbH
`Bruehlstrasse 50
`
`76297 Stutensee, Germany
`Tel; +49 (0) 72 4995 2063
`Fax: +49 (0) 72 4995 2064
`
`c E
`0344
`
`VSIMDT00027345
`
`Teleflex Ex. 2061
`Medtronic v. Teleflex
`
`IPR2020-00131
`
`
`Page 4
`
`Teleflex Ex. 2061
`Medtronic v. Teleflex
`IPR2020-00131
`
`