`BEFORE THE PATENT TRIAL AND APPEAL BOARD
`
`
`
`
`
`
`
`
`
`
`
`
`
`
`
`
`
`
`
`
`MEDTRONIC, INC.
`Petitioner
`
`v.
`
`NUVASIVE, INC.
`Patent Owner
`
`
`
`
`
`
`
`
`
`
`
`
`
`
`
`
`Case IPR2013-00506
`Patent 8,361,156
`
`
`
`
`
`
`
`
`NUVASVE INC.’S
`PATENT OWNER RESPONSE
`
`ALPHATEC HOLDINGS, INC., ALPHATEC SPINE INC., IPR2019-00362, Ex. 1043, p. 1 of 67
`
`
`
`Patent No. 8,361,156
`Patent Owner Response
`
`
`
`TABLE OF CONTENTS
`
`Case IPR2013-00506
`Attorney Docket No: 13958-0116IP2
`
`I.
`II.
`III.
`
`IV.
`
`V.
`
`VI.
`
`INTRODUCTION ......................................................................................................... 1
`BOARD’S DECISION TO INSTITUTE REVIEW ......................................................... 2
`BACKGROUND ........................................................................................................... 4
`A.
`Background of modern implant design ............................................................ 4
`B.
`Background of implant sizing ........................................................................... 6
`C.
`Background of radiopaque implant markers .................................................. 12
`D.
`Background of the ‘156 patent ....................................................................... 14
`SUMMARY OF THE PRIOR ART ............................................................................. 17
`A.
`Telamon (Ex. 1107 and 1108) ....................................................................... 17
`B.
`SVS-PR (Ex. 1106) ........................................................................................ 21
`C.
`Baccelli (Ex. 1104) ......................................................................................... 25
`D.
`Michelson (Ex. 1105) ..................................................................................... 27
`E.
`Saber (Ex. 1101, Appendix A) ....................................................................... 31
`CLAIM 1 IS NOT RENDERED OBVIOUS BY THE PRIOR ART .............................. 32
`A.
`None of the prior art references discloses a posterior implant with a pair of
`radiopaque markers in the medial plane. ....................................................... 33
`The cited references provide no motivation or reasoning to add a pair of
`radiopaque markers in the medial plane of posterior implants ...................... 36
`It is not obvious to modify SVS-PR or Telamon to include a pair of radiopaque
`markers in the medial plane. .......................................................................... 37
`CLAIM 5 IS NOT RENDERED OBVIOUS BY THE PRIOR ART .............................. 47
`A.
`SVS-PR and Telamon Are PLIF Implants Intended for PLIF Usage ............. 47
`B.
`Modifying the Posterior Implants in SVS-PR and Telamon to Exceed 40 mm
`Would Render Them Inoperable For Their Intended Purpose ....................... 49
`i
`
`C.
`
`B.
`
`ALPHATEC HOLDINGS, INC., ALPHATEC SPINE INC., IPR2019-00362, Ex. 1043, p. 2 of 67
`
`
`
`Patent No. 8,361,156
`
`Case IPR2013-00506
`Patent Owner Response
`
`Attorney Docket No: 13958-0116IP2
`VII. CLAIM 9 IS NOT RENDERED OBVIOUS BY THE PRIOR ART .............................. 57
`A.
`SVS-PR and Telamon Are PLIF Implants Intended for PLIF Usage ............. 57
`B.
`Modifying the Posterior Implants in SVS-PR and Telamon to be 18 mm in
`Width Would Render Them Inoperable For Their Intended Purpose ............ 57
`VIII. CONCLUSION .......................................................................................................... 59
`CERTIFICATE OF SERVICE ........................................................................................
`
`
`
`ii
`
`ALPHATEC HOLDINGS, INC., ALPHATEC SPINE INC., IPR2019-00362, Ex. 1043, p. 3 of 67
`
`
`
`Patent No. 8,361,156
`Patent Owner Response
`
`Case Law
`
`
`
`TABLE OF AUTHORITIES
`
`Case IPR2013-00506
`Attorney Docket No: 13958-0116IP2
`
`KSR Int’l Co. v. Teleflex Inc., 550 U.S. 398, 418-19 (2007) ............................... 17, 36, 39, 44
`
`In re Kahn, 441 F.3d 977, 988 (Fed. Cir. 2006) ................................................................... 36
`
`W.L. Gore & Associates, Inc. v. Garlock, Inc., 721 F.2d 1540, 1553 (Fed. Cir. 1983) ... 38, 56
`
`In re Gordon, 733 F.2d 900, 902 (Fed. Cir. 1984) ................................................... 49, 55, 58
`
`DePuy Spine, Inc. v. Medtronic Sofamor Danek, Inc., 567 F.3d 1314, 1326-29 (Fed. Cir.
`2009) .................................................................................................................. 49, 58
`
`In re Ratti, 270 F.2d 810, 813 (CCPA 1959) ................................................................. 55, 56
`
`Decisions of the Patent Trial and Appeal Board
`
`Plas-Pak Industries, Inc. v. Sulzer Mixpac AG, 2014 WL 203101 ........................................ 50
`(Patent Tr. & App. Bd.)
`
`Ex Parte Shufflebotham, et al., 2013 WL 5409872 (Patent Tr. & App. Bd.) ......................... 50
`
`Ex Parte Landschaft, et al., 2013 WL 603815 (Patent Tr. & App. Bd.) ................................ 50
`
`Ex Parte Atsuumi, et al., 2013 WL 1331590 (Patent Tr. & App. Bd.) ................................... 50
`
`Statutes
`
`35 U.S.C. § 103 .................................................................................................................. 2, 3
`
`Rules and Regulations
`
`37 CFR § 42.107(c) ............................................................................................................... 2
`
`37 C.F.R. § 42.22(a)(2) ......................................................................................................... 44
`
`
`
`iii
`
`ALPHATEC HOLDINGS, INC., ALPHATEC SPINE INC., IPR2019-00362, Ex. 1043, p. 4 of 67
`
`
`
`Patent No. 8,361,156
`Patent Owner Response
`
`
`
`EXHIBITS
`
`Case IPR2013-00506
`Attorney Docket No: 13958-0116IP2
`
`Exhibit Description
`Ex. #
`NUVA 2101 U.S. Patent No. 7,905,840 to Pimenta et al.
`NUVA 2102 Declaration in Support of the Pro Hac Vice Admission of Michael A. Amon;
`Declaration of Charles Forthaus (Not Filed)
`NUVA 2103 Vetebral Spacer-PR Brochure (Not Filed)
`NUVA 2104
`Forthaus Memo regarding Vertebral Spacer-PR Brochure (Not Filed)
`NUVA 2105 myspinetools.com front page (Not Filed)
`NUVA 2106 myspinetools.com Terms of Use (Not Filed)
`NUVA 2107
`Launch Binder (Not Filed)
`NUVA 2108 Webpage Toad MySQL (Not Filed)
`NUVA 2109 Reserved
`NUVA 2010 U.S. Patent 8,512,408 (Hynes) (Not Filed)
`NUVA 2011 Synthes SVS-PR Guide
`NUVA 2012 Medtronic Sofamor Danek Boomerang brochure
`NUVA 2013 Hynes Deposition Transcript
`NUVA 2014
`510(k) Summary Medtronic Sofamor Danek K122037
`NUVA 2015
`510(k) Summary Telamon® PEEK Spinal System K110562
`NUVA 2016 Synthes Vertebral Spacer – AR Brochure
`NUVA 2017 DePuy Spine Saber Surgical Technique Brochure
`NUVA 2018 Declaration of Barton L. Sachs, M.D. in IPR2013-00206
`NUVA 2019 Moro, et al., “An Anatomic Study of the Lumbar Plexus with Respect to
`Retroperitoneal Endoscopic Surgery”
`
`iv
`
`ALPHATEC HOLDINGS, INC., ALPHATEC SPINE INC., IPR2019-00362, Ex. 1043, p. 5 of 67
`
`
`
`Patent No. 8,361,156
`Patent Owner Response
`
`
`
`
`Case IPR2013-00506
`Attorney Docket No: 13958-0116IP2
`
`NUVA 2020 Declaration of Dr. Hansen A. Yuan, M.D.
`NUVA 2021 Curriculum Vitae of Dr. Hansen A. Yuan, M.D.
`NUVA 2022 NuVasive - CoRoent XL Brochure
`NUVA 2023 Redacted Engineering Drawings
`NUVA 2024 Redacted Deposition of Steven DeRidder
`NUVA 2025 Clydesdale® Spinal System Brochure
`NUVA 2026 Clydesdale® Spinal System Images
`NUVA 2027 Medtronic Direct Lateral Interbody Fusion DLIF Surgical Technique
`Brochure
`NUVA 2028 Medtronic DILF-Direct Lateral Interbody Fusion Brochure
`NUVA 2029 Clydesdale® Spinal System Image
`NUVA 2030 Declaration of Patrick Miles
`
`
`
`
`
`
`
`
`
`
`
`
`
`
`v
`
`ALPHATEC HOLDINGS, INC., ALPHATEC SPINE INC., IPR2019-00362, Ex. 1043, p. 6 of 67
`
`
`
`Patent No. 8,361,156
`Patent Owner Response
`I.
`INTRODUCTION
`Medtronic, Inc. (“Medtronic”) seeks inter partes review of U.S. 8,361,156 (“the ‘156
`
`Case IPR2013-00506
`Attorney Docket No: 13958-0116IP2
`
`
`
`
`patent”), which was asserted against Medtronic in a counterclaim of a lawsuit initiated by
`
`Medtronic. The claims of the ‘156 patent are tailored to a unique combination of features
`
`collectively provided in a spinal implant—features particularly suited for implant insertion in
`
`a lateral, trans-psoas surgical approach path. Yuan Decl. (Ex. 2020), ¶ 47; Ex. 1115, 5:29-
`
`31. The implant depicted in the ‘156 patent was the first lateral, trans-psoas fusion implant
`
`that achieved commercial success, and it pioneered a surgical method that changed the
`
`entire U.S. market for lumbar fusion procedures. Miles Decl. (Ex. 2030), ¶ 9; Yuan Decl., ¶¶
`
`48-49. Indeed, the lack of any anticipatory references in Medtronic’s Petition underscores
`
`the novelty of the claimed invention and the fact that this unique combination of features
`
`recited in the ‘156 patent claims were never previously implemented in a single implant.
`
`Petitioner’s obviousness arguments in this proceeding alleged that traditional
`
`posterior lumbar interbody fusion (“PLIF”) implants, such as the Telamon and SVS-PR
`
`implants, would be modified to borrow elements of Baccelli’s anterior cervical implant in a
`
`way that was never previously conceived or suggested merely because the SVS-PR, the
`
`Telamon, and the Baccelli implants are “from the same field of artificial spinal implants used
`
`in spinal fusion.” See, e.g., Ex. 1101, ¶¶ 68, 70, 72, 74, 99, 106. This is not enough.
`
`Petitioner’s position that it is obvious to create implants with virtually any combination of
`
`design features in any orientation ignores the basic fact that interbody fusion implant
`1
`
`
`
`ALPHATEC HOLDINGS, INC., ALPHATEC SPINE INC., IPR2019-00362, Ex. 1043, p. 7 of 67
`
`
`
`Patent No. 8,361,156
`
`Case IPR2013-00506
`Patent Owner Response
`
`Attorney Docket No: 13958-0116IP2
`designers employ a time-consuming and rigorous process of research, testing, and analysis
`
`when choosing features, size, and shape for each commercial implant design—all centered
`
`on the intended use (insertion approach and final resting position for vertebral fusion) of the
`
`implant. See Yuan Decl., ¶ 40; Ex. 2013, ¶ 44:19-47:19. Consequently, ordinary implant
`
`designers do not modify, move, or add elements to commercial, FDA-approved interbody
`
`fusion implants haphazardly—they require a concrete and important reason to do so.
`
`Petitioner’s proposed obviousness grounds include no articulated reasoning with a rationale
`
`underpinning to modify the traditional PLIF block implants in a way that would result in the
`
`implant of claim 1.
`
`II.
`
`BOARD’S DECISION TO INSTITUTE REVIEW
`On February 13, 2014, the Board instituted inter partes review of U.S. 8,361,156
`
`(“the ‘156 patent”). Based on unrebutted declarant testimony only from Petitioner,1 the
`
`Board concluded that Petitioner had demonstrated a “reasonable likelihood” that it will
`
`prevail on the challenges and granted review on the following grounds:
`
` Claims 1–4, 7, 8, 10–14, 19, 20, 23, 24, 26, and 27 as obvious under 35 U.S.C. §
`
`103 by the combination of SVS-PR and Baccelli;
`
`
`
`1 37 CFR § 42.107(c) prohibits new testimony evidence in the preliminary response.
`
`
`
`2
`
`ALPHATEC HOLDINGS, INC., ALPHATEC SPINE INC., IPR2019-00362, Ex. 1043, p. 8 of 67
`
`
`
`Patent No. 8,361,156
`Patent Owner Response
`
`
`
`
`Case IPR2013-00506
`Attorney Docket No: 13958-0116IP2
`
` Claims 5, 6, and 9 as obvious under 35 U.S.C. § 103(a) by the combination of SVS-
`
`PR, Baccelli, and Michelson;
`
` Claim 25 as obvious under 35 U.S.C. § 103(a) by the combination of SVS-PR,
`
`Baccelli, and Telamon;
`
` Claims 1–4, 7, 10–14, 19, 20, and 23–27 as obvious under 35 U.S.C. § 103(a) by the
`
`combination of Telamon and Baccelli; and
`
` Claims 5, 6, 8, and 9 as obvious under 35 U.S.C. § 103(a) by the combination of
`
`Telamon, Baccelli, and Michelson.
`
`Feb. 13, 2014 Decision in IPR2013-00506 (“Decision”), p. 19-20. Throughout the Decision,
`
`the Board recognized that Patent Owner only presented attorney argument and noted that
`
`there was no supporting evidence. For example, in response to Patent Owner’s argument
`
`that one proposed modification would render the SVS-PR implant inoperable for its intended
`
`purpose, the Board stated: “[i]t is, therefore, not known, without additional evidence, if the
`
`distance from the posterior to anterior edges of the disc space in SVS is less than, equal to,
`
`or greater than 40 mm.” Id. at 13. The Board also noted that Patent Owner did not provide
`
`evidence “to show that using an implant that is greater than 40 mm in length would” injure
`
`the patient. Id. at 13-14 (“without additional evidence”).
`
`The Board will find the positions in this Response fully supported by evidence,
`
`including the evidence identified as lacking in the Decision.
`
`
`
`3
`
`ALPHATEC HOLDINGS, INC., ALPHATEC SPINE INC., IPR2019-00362, Ex. 1043, p. 9 of 67
`
`
`
`
`
`
`Patent No. 8,361,156
`Patent Owner Response
`III.
`BACKGROUND
`A.
`Background of modern implant design
`Spinal fusion implants are created via a time-consuming and rigorous process of
`
`Case IPR2013-00506
`Attorney Docket No: 13958-0116IP2
`
`research, testing, and analysis. Yuan Decl., ¶¶ 39-41; see also Hynes Depo. (Ex. 2013),
`
`45:9-46:4, 46:16-47:2. This is most certainly true for commercially available, FDA-approved
`
`interbody spinal fusion implants, which have specific sizes, surface features, apertures,
`
`tooling engagement structures, and other features specifically associated with the
`
`designer’s intended use of the spinal implant. Yuan Decl., ¶¶39-40. In fact, prior to 2004
`
`and still to this day, nearly all commercially available spinal implants were provided with
`
`surgical “guide” literature so as to instruct spinal surgeons on the intended use of the
`
`commercial implant. This was certainly true for the Telamon implant and the SVS-PR
`
`implant cited in the Petition. See Ex. 1108 (Telamon “guide”); Ex. 2011 (SVS-PR “guide”).
`
`Even slight changes to the design of a commercially available interbody fusion implant,
`
`especially the dimensions and marker orientation/positioning, can have a dramatic effect on
`
`the functionality and intended use of the implant (and possibly FDA scrutiny), and any
`
`ordinary implant designer understands this fact. Yuan Decl., ¶ 40.
`
`It is not only important that the implant be designed just right, but it is critical that the
`
`implant also be used just right. Yuan Decl., ¶¶ 38-40. Interbody spinal fusion implants and
`
`spinal access equipment are designed to be used by average surgeons in specific a
`
`medical procedure according to very a specific technique. Yuan Decl., ¶ 39; see also
`4
`
`
`
`ALPHATEC HOLDINGS, INC., ALPHATEC SPINE INC., IPR2019-00362, Ex. 1043, p. 10 of 67
`
`
`
`Patent No. 8,361,156
`
`Case IPR2013-00506
`Patent Owner Response
`
`Attorney Docket No: 13958-0116IP2
`Hynes Depo. 44:9-11. Spinal fusion implants are designed not as universal tools usable by
`
`ordinary surgeons to freelance in new and exciting ways. Yuan Decl., ¶ 39. They are
`
`designed according to a specific use that is safe, effective, and reproducible in the hands of
`
`all surgeons—not just the most highly skilled and experimental group of surgeons, but also
`
`the ordinary surgeon that is faithful to the surgical “guide” and other related literature. Yuan
`
`Decl., ¶ 39. Surgeons receive extensive training using spinal implants (including the
`
`intended approach path to the spine) and spinal access equipment such that every surgeon
`
`can follow the procedure to achieve the identical, reproducible result that is (hopefully) safe
`
`and very effective. Yuan Decl., ¶¶ 39, 52. This reproducibility is such a critical aspect of
`
`interbody fusion implant design because it means not that the procedure might be safe
`
`sometimes but that it will be safe in the hands of ordinary surgeons (not just a small group
`
`of the most highly skilled spine surgeons). Yuan Decl., ¶¶ 39, 52.
`
`Even small design modifications to the dimensions and marker
`
`orientation/positioning of an interbody fusion implant make a big difference from a clinical
`
`perspective. Yuan Decl., ¶ 40. For interbody fusion implants, it is critically important that
`
`the implant fits where it is supposed to fit along the intended insertion path, can be
`
`positioned as it is supposed to be positioned, supports the load that it is supposed to
`
`support, aligns the spine as it is supposed to align the spine, stays in place where it is
`
`supposed to stay, and allows the spine to fuse and heal the way the spine is supposed to
`
`fuse and heal. Yuan Decl., ¶ 41. The difference between meeting all of these requirements
`5
`
`
`
`ALPHATEC HOLDINGS, INC., ALPHATEC SPINE INC., IPR2019-00362, Ex. 1043, p. 11 of 67
`
`
`
`Patent No. 8,361,156
`
`Case IPR2013-00506
`Patent Owner Response
`
`Attorney Docket No: 13958-0116IP2
`and meeting only some of them is the difference between having a great implant and having
`
`an implant that is unsuitable for its intended purpose. Yuan Decl., ¶ 41. Small design
`
`changes to the dimensions and marker orientation/positioning can and do have unintended
`
`effects that negatively affect the performance of the spinal interbody fusion implant. Yuan
`
`Decl., ¶ 40. This is why ordinary implant designers are so careful about such design
`
`changes to commercially available, FDA-approved implants, and would not be prompted to
`
`modify such a commercially available implant in a manner that would prevent or otherwise
`
`reduce the safety of its original intended use. Yuan Decl., ¶¶ 40, 103, 105.
`
`This background is important to understanding how and why persons of ordinary skill
`
`in the art design implants the way they do. There are different commercially available
`
`implant designs in the prior art (and in this proceeding) not because “any-old-design will
`
`work,” but because each particular design was determined to be the right design for that
`
`particular intended use set forth in the surgical “guide” literature. Yuan Decl., ¶ 39.
`
`Background of implant sizing
`B.
`The size of a spinal interbody fusion implant is extremely important for the
`
`performance of the implant and for the intended insertion path of the implant. Yuan Decl.,
`
`¶¶35, 39-41. In general, spinal fusion interbody implants need to be small—on the order of
`
`millimeters. See e.g. Ex. 1115, claims 5 and 9; Ex. 1105, 10:41-47; Ex. 1106, p. 1; Ex.
`
`1107, p. 2. Spinal fusion interbody implants are small for a number of reasons related to
`
`human anatomy in and near the spinal column. Yuan Decl., ¶¶ 34, 35. For example, spinal
`6
`
`
`
`ALPHATEC HOLDINGS, INC., ALPHATEC SPINE INC., IPR2019-00362, Ex. 1043, p. 12 of 67
`
`
`
`Patent No. 8,361,156
`
`Case IPR2013-00506
`Patent Owner Response
`
`Attorney Docket No: 13958-0116IP2
`fusion interbody implants are designed to reside in the disc space between vertebrae and
`
`replace a vertebral disc, which are relatively small in humans (again, on the order of
`
`millimeters). See Ex. 1113, p. 4; Yuan Decl., ¶ 30, 34.
`
`Vertebral body, Ex. 1113, p. 3
`
`
`
`Critical anatomy exists near the surgical location, which can force further size
`
`constraints. Yuan Decl., ¶¶ 26-30, 34, 35. For example, the spinal cord passes through the
`
`spinal canal toward the posterior (rear) portion of the vertebrae. Yuan Decl., ¶ 26, 28.
`
`Damaging the spinal cord can paralyze a patient and is a very real risk during spinal fusion
`
`procedures. Yuan Decl., ¶ 34, 111. Accordingly, implants (and insertion tools) are sized to
`
`avoid contact with the spinal cord during and after implantation. Yuan Decl., ¶ 34, 35. This
`
`especially constrains implant size in posterior procedures, such as a PLIF (posterior lumbar
`
`interbody fusion) procedure. Yuan Decl., ¶ 35. PLIF procedures for two of the prior art
`
`implants (SVS-PR and Telamon) are illustrated below.
`
`
`
`7
`
`ALPHATEC HOLDINGS, INC., ALPHATEC SPINE INC., IPR2019-00362, Ex. 1043, p. 13 of 67
`
`
`
`Patent No. 8,361,156
`Patent Owner Response
`
`
`
`
`Case IPR2013-00506
`Attorney Docket No: 13958-0116IP2
`
`
`
`
`SVS-PR Implant (Ex. 2011) and Telamon Implant (Ex. 1108)
`
`Such PLIF implants are narrow so that two such PLIF implants can be inserted in
`
`direct posterior paths on opposite sides of the spinal canal and positioned side by side in
`
`the disc space. Yuan Decl., ¶¶ 99, 111-113. The SVS-PR and Telamon implants are
`
`reproduced below at actual size2 to illustrate just how small such implants are.
`
`
`
`
`
`
`
`
`SVS-PR Implant (Exhibit 1106) and Telamon Implant (Ex. 1108) (annotated)
`
`
`
`2 These images are sized so as to be the actual dimension disclosed in Ex. 1106-1108
`
`when printed on 8 ½ by 11 inch paper.
`
`
`
`8
`
`ALPHATEC HOLDINGS, INC., ALPHATEC SPINE INC., IPR2019-00362, Ex. 1043, p. 14 of 67
`
`
`
`Patent No. 8,361,156
`
`Case IPR2013-00506
`Patent Owner Response
`
`Attorney Docket No: 13958-0116IP2
`Critical anatomy also include nerves and nerve roots near the vertebrae, including
`
`sensitive nerve roots passing through the psoas muscles lateral to (toward the sides of) the
`
`lumbar vertebrae. Yuan Decl., ¶ 26, ; Ex. 2019, Moro et al., An anatomic study of the
`
`lumbar plexus with respect to retroperitoneal endoscopic surgery, SPINE Vol. 28 (2003), pp.
`
`423, 428 (showing that Medtronic’s agent, Dr. Mathews, expressed the conventional
`
`wisdom in the prior art that “surgeons have not felt comfortable with dissecting the psoas
`
`because of the presence of the lumbar plexus”). Damaging such nerve roots can also
`
`paralyze or otherwise permanently harm a patient. Yuan Decl., ¶49. There are also blood
`
`vessels on different sides of the vertebrae, including particularly critical vessels anterior
`
`(front) of the vertebrae. Yuan Decl., ¶¶ 26, 34-35. Damaging one of those blood vessels
`
`puts a patient’s life at risk. Yuan Decl., ¶¶34-35, 98. Consequently, spinal fusion implants
`
`are sized small enough to avoid damaging critical blood vessels and spinal nerves during
`
`and after the implantation procedure. Yuan Decl., ¶¶34-35, 48-52, 98, 111.
`
`While it is desirable for implants to be large, the implant designs must still facilitate
`
`their intended use (PLIF procedure, ALIF procedure, TLIF procedure, etc.) within the
`
`anatomical/clinical constraints described above. Yuan Decl., ¶¶ 35, 40-41. Larger spinal
`
`fusion implants have a larger footprint and more material for structurally supporting and
`
`properly spacing adjacent vertebrae. Yuan Decl., ¶ 41; see also Ex. 1107, p. 2 (advertising
`
`“[h]igh ultimate strength” and providing load, fatigue, and stiffness data); Ex. 1106, p. 2
`
`(providing data on expulsion strength, compressive strength, fatigue); Ex. 1105, 6:43-57
`9
`
`
`
`ALPHATEC HOLDINGS, INC., ALPHATEC SPINE INC., IPR2019-00362, Ex. 1043, p. 15 of 67
`
`
`
`Patent No. 8,361,156
`
`Case IPR2013-00506
`Patent Owner Response
`
`Attorney Docket No: 13958-0116IP2
`(touting the importance of length and width for creating a “much greater surface area of
`
`contact”). If an implant is too small, the implant can fail to properly support the vertebrae
`
`and cause pain (for example pinched nerves) that is even greater than the pain the spinal
`
`fusion procedure was intended to cure. Yuan Decl., ¶ 41.
`
`The conflict between the benefits of a large implant and those of a small implant
`
`force designers to undertake critical analysis, research, and testing when designing a spinal
`
`fusion implant. Yuan Decl., ¶¶ 39-41. These constraints, in addition to shape requirements
`
`that are necessary or desirable for a specific procedure or patient condition as well as other
`
`implant features causes the process of designing an implant to be complex and rigid in that
`
`even slight changes to the implant dimensions and radiopaque marker structure/positioning
`
`can have significant clinical problems. Yuan Decl., ¶40. Determining superior implant
`
`dimensions can be an extremely difficult process, especially when attempting to design
`
`implants for relatively new spinal fusion procedures that have no conventional implant
`
`design to emulate. Yuan Decl., ¶¶ 48-52. There is no guarantee that a designer will get it
`
`right. Yuan Decl., ¶¶ 50-52. Indeed, as described below for purposes of a laterally inserted
`
`implant, the Michelson patent illustrates several examples of theorized lateral implant
`
`designs that were improperly sized and shaped, recognized in the art as unsafe, and never
`
`implemented for insertion into a live human patient.
`
`In 2004, spinal fusion via a lateral (often called “direct lateral” or “extreme lateral”)
`
`access path was one of those procedures without a conventional implant design. Yuan
`10
`
`
`
`ALPHATEC HOLDINGS, INC., ALPHATEC SPINE INC., IPR2019-00362, Ex. 1043, p. 16 of 67
`
`
`
`Patent No. 8,361,156
`
`Case IPR2013-00506
`Patent Owner Response
`
`Attorney Docket No: 13958-0116IP2
`Decl., ¶¶ 48-49. While lateral fusion procedures had been performed by a handful of highly
`
`skilled surgeons for years, such procedures were relatively rare and were not performed
`
`(especially in the lumbar spine) by ordinary spine surgeons. See, e.g., Yuan Decl., ¶51.
`
`This was, in part, due to reluctance by surgeons to traverse the psoas muscle for fear of
`
`damaging nerve roots that extend therethrough. Yuan Decl., ¶49; Ex. 2019, p. 428
`
`(“surgeons have not felt comfortable with dissecting the psoas because of the presence of
`
`the lumbar plexus”). Consequently, there was no appreciable market for lateral spinal
`
`fusion implants, and importantly, there was no conventional or standard design at that time.
`
`Yuan Decl., ¶¶ 49-52.
`
`Dr. Gary Michelson, the inventor of the Michelson patent (Ex. 1105) was one of
`
`those people trying to design lateral implants. See Ex. 1105; Yuan Decl., ¶50. There are a
`
`number of implant designs illustrated in Michelson (see Ex. 1105, Figs. 1-20) but they were
`
`not commercialized, and it is well known to both parties here that not even Dr. Michelson
`
`inserted such an implant in a live human patient. Michelson discloses what Dr. Michelson
`
`mistakenly believed to be appropriate sizes for lateral implants for use in the lumbar spine
`
`for dowel implants (see Ex. 1105, 7:21-26) and for more rectangular implants (see Ex. 1105,
`
`10:41-47). But Dr. Michelson’s proposed overall length and width combinations, along with
`
`the shapes, for his lateral lumbar implants were recognized in 2004 and earlier as being
`
`wrong, unsafe, or both, which is one reason why those proposed sizes are not ultimately
`
`practiced in the industry. Yuan Decl., ¶50. The Michelson patent never illustrated any
`11
`
`
`
`ALPHATEC HOLDINGS, INC., ALPHATEC SPINE INC., IPR2019-00362, Ex. 1043, p. 17 of 67
`
`
`
`Patent No. 8,361,156
`
`Case IPR2013-00506
`Patent Owner Response
`
`Attorney Docket No: 13958-0116IP2
`implant design that was safe and feasible for lateral insertion, so even in the “post-
`
`Michelson” (a new term used repeatedly by the Petitioner) time frame before 2004, the
`
`industry was left with nothing more than wrong answers and a general avoidance by
`
`average spine surgeons of any lateral, trans-psoas surgeries. Dr. Michelson’s sizes are
`
`also not the sizes disclosed in the ‘156 patent for a laterally insertion implant, as will be
`
`discussed below. Yuan Decl., ¶¶ 90-91. Michelson is, therefore, one example of the
`
`reality that knowing an intended direction of insertion for a spinal fusion implant does not
`
`make it easy (or obvious) to select appropriate implant dimensions. Yuan Decl., ¶¶50-52.
`
`Background of radiopaque implant markers
`C.
`Radiopaque markers are called “radiopaque” because they are “opaque” when
`
`viewed via X-ray imaging. Yuan Decl., ¶¶42-46; Ex. 1115, FIG. 21. Patent Owner does not
`
`dispute that radiopaque markers have long been used in implantable medical devices to
`
`show positioning of such devices, both during and after the implantation procedure.
`
`Radiopaque markers are traditionally positioned at the extremities of spinal implants to
`
`show the location of those extremities. Yuan Decl., ¶45. For example, elongated implants
`
`such as the Telamon and SVS-PR would traditionally include a radiopaque marker at each
`
`lengthwise end. Yuan Decl., ¶¶ 78-82 and 83-86. These two markers allow the surgeon to
`
`ensure that each end is at the appropriate position with respect to the vertebrae, usually
`
`along a hardened bone region near the rim of the vertebrae. Yuan Decl., ¶¶ 81 and 86.
`
`
`
`12
`
`ALPHATEC HOLDINGS, INC., ALPHATEC SPINE INC., IPR2019-00362, Ex. 1043, p. 18 of 67
`
`
`
`Patent No. 8,361,156
`
`Case IPR2013-00506
`Patent Owner Response
`
`Attorney Docket No: 13958-0116IP2
`Dr. Hynes also confirmed that putting “one on one end and one on the other end” of
`
`a PLIF implant is what he would do and “what’s commonly done.” Hynes Depo., 138:16-22.
`
`Dr. Hynes explained the purpose of putting radiopaque markers at each lengthwise end of a
`
`PLIF implant as follows: “if you have one marker on the other end, then you can follow the
`
`distal or the leading edge in and see where it is and then you have a marker on the trailing
`
`end and see where it ends up.” Hynes Depo., 142:1-5. Dr. Hynes further explained that
`
`ordinary surgeons would also “pick the front and the back in the direction of insertion. It's
`
`just intuitive, but it's also safer for the patient.” Hynes Depo., 142:8-12.
`
`The location of implant markers is very intentional to convey specific information to
`
`the implanting surgeons. Yuan Decl., ¶46. While it is technically possible from a
`
`manufacturing standpoint to add radiopaque markers to a PEEK implant in virtually an
`
`infinite number of different positions, the positions actually selected are very deliberate and
`
`purposeful based upon the original intended use (insertion path and final resting position) of
`
`the implant. Yuan Decl., ¶¶ 45-46. Because of this, extra markers are simply not added
`
`without a specific purpose. Id. The testimony evidence here from both parties shows the
`
`agreement that excess markers positioned in an implant at unnecessary locations can
`
`clutter and confuse x-ray imaging viewed by the surgeon. Yuan Decl., ¶¶ 45-46, 98-99, and
`
`102; Hynes Depo., 163:23-164:25. Indeed, when asked about adding additional markers
`
`across the medial center of a traditional PLIF implant, Dr. Hynes also agreed that such
`
`
`
`13
`
`ALPHATEC HOLDINGS, INC., ALPHATEC SPINE INC., IPR2019-00362, Ex. 1043, p. 19 of 67
`
`
`
`Patent No. 8,361,156
`
`Case IPR2013-00506
`Patent Owner Response
`
`Attorney Docket No: 13958-0116IP2
`additional markers could create redundancy or confusion. Hynes Depo., 163:23-164:25.
`
`Dr. Hynes explained:
`
`What happens is the wrong marker, the size of the marker, direction of the
`marker, and the wrong place actually creates confusion sometimes. You'd
`see less. Sometimes less is better. We have to look at it.
`And so there's all kinds of combinations you could use and we could make
`them different sizes, different shapes, but then you start getting too much
`information and it actually gives you a less information.
`Hynes Depo., 164:10-19 (emphasis added). In order to convey specific information without
`
`creating confusion, designers carefully and critically select the number and location of
`
`radiopaque markers in each implant based upon the implant’s intended clinical use, not
`
`merely because a metallic marker could be manufactured anywhere into a plastic structure.
`
`Yuan Decl., ¶ 46. The number and position of radiopaque markers in a radiolucent implant
`
`is dictated and limited by the intended clinic use of that implant, not by manufacturing
`
`capabilities. Petitioner, and its alleged expert Dr. Hynes, appear to ignore this reality of
`
`interbody fusion implant design. Hynes Depo., 140:23-141:13 (relying on the possible
`
`manufacturing simplicity, not the clinical purpose of such markers, and stating “[t]hey’re [the
`
`markers are] easy to put in….You can have any choice you want.”)
`
`Background of the ‘156 patent
`D.
`The claims of the ‘156 patent do not broadly claim all lateral fusion implants. They
`
`do not claim all radiolucent implants having multiple radiopaque markers. They do not claim
`
`
`
`14
`
`ALPHATEC HOLDINGS, INC., ALPHATEC SPINE INC., IPR2019-00362, Ex. 1043, p. 20 of 67
`
`
`
`Patent No. 8,361,156
`
`Case IPR2013-00506
`Patent Owner Response
`
`Attorney Docket No: 13958-0116IP2
`an