`
`LLuummooggeenn®® FF DDyyeess
`
`LLuummooggeenn®® FF YYeellllooww 008833
`
`Colorants & Additives for Plastics
`
` 36 Riverside Ave Rensselaer, NY 12144 (519) 472-8300
` Toll-Free 1-877-747-1857
`
`Nichia EX2017
`
`
`
`0.02% GPPS
`
`LUMOGEN® F Yellow 083
`
`Type of Dye
`
`Color Index
`
`
`
`Perylene
`
`
`
`------------------------
`
`Heat Stability (GPPS)
`
`280° C
`
` >90
`Fastness to weathering(PMMA)
`*0.02% in PMMA injection-molded plaques of 2 mm thickness
`Residual Fluorescence(%) after 80 days accelerated exposure in the
`Xenotest 1200
`
`Specific Gravity
`
`1.27 cm3
`
`Max (nm) Absorption
`in ethylene dichloride
`
` Max (nm) Absorption
` in PMMA
`
`Fluorescence Max(nm Quantum
`in ethylene dichloride
`Yield
`
`476
`
`473
`
`490
`
`0.91
`
`LUMOGEN® F Yellow 083
`Spectral curve run in Acetone
`
`480
`
`2.00
`
`1.60
`
`1.20
`
`0.80
`
`0.40
`
`Absorbance
`
`0.00
`200
`
`300
`
`400
`
`500
`Wavelength(nm)
`
`600
`
`700
`
`800
`
`Nichia EX2017
`
`
`
`LUMOGEN® F Yellow 083
`Fluorescence curve run in Acetone
`
`350 400
`
`450 500 550
`Wavelength(nm)
`
`600 650 700 750 800
`
`80.00
`70.00
`60.00
`50.00
`40.00
`30.00
`20.00
`10.00
`0.00
`250 300
`
`Safety
`
`We know of no ill effects that could have resulted from using
`LUMOGEN® F Dyes for the purpose for which it is intended and from
`processing it in accordance with current practice.
`
`According to the experience that we have gained over many years and
`other information at our disposal LUMOGEN® F Dyes, do not exert any
`harmful effects on health, provided that it is used properly, due attention
`is given to the precautions necessary for handling chemicals, and the
`information and advice given in our Safety Data sheet are observed.
`
`Note
`The information submitted in this publication is based on our current
`knowledge and experience. In view of the many factors that may affect
`processibility and application, these data do not relieve processors
`from the responsibility of carrying out their own tests and experiments;
`neither do they imply any legally binding assurance of certain
`properties or suitability for a specific purpose. It is the responsibility of
`those to whom we supply our products to ensure that any proprietary
`rights and existing laws and legislation are observed.
`
`The information contained herein is based on data and information developed in the laboratory of BASF Corporation,("Seller"), but is presented
`without guarantee or warranty and the Seller disclaims any liability incurred from the use thereof. Nothing contained herein is to be construed as a
`recommendation for any use, including without limitation, any use in a commercial process not controlled by the Seller, nor for a use which is in
`violation of any existing patent, foreign or domestic, of applicable laws and regulators. THE SELLER MAKES NO WARRANTIES, EXPRESS OR
`IMPLIED, INCLUDING, BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE,
`EXCEPT AS EXPRESSLY STATED IN SELLER'S SALES CONTRACT OR SALES ACKNOWLEDGMENT FORM.
`
`BASF CORPORATION
`
`BASF
`
`Nichia EX2017
`
`