Instruction Sheet
`for the PASCO
`Model OS-9286A
`
`012-02262H
`
`MERCURY VAPOR LIGHT SOURCE
`
`Rails for Mounting Filter
`
`Remove screws shown in
`black (8), then remove plate
`to inspect or replace lamp.
`
`To
`115 VAC, 60 Hz
`or
`220 VAC, 50Hz
`
`Hg
`
`LIGHT
`SOURCE
`OS-9286
`
`ON
`
`OFF
`
`DISCONNECT INPUT POWER
`BEFORE REPLACING FUSE.
`FOR CONTINUED FIRE PROTECTION
`REPLACE ONLY WITH 4.0A, 250 V,
`TYPE T FUSE, (PER IEC 127-2/III).
`
`LINE VOLTAGE RANGE: 108 - 132 VAC
`POWER: 125 W MAX
`FREQ.: 47 - 63 HZ
`
`~
`115 VOLTS
`
`FOR CONTINUED FIRE PROTECTION
`REPLACE ONLY WITH 2.0A, 250 V,
`TYPE T FUSE, (PER IEC 127-2/III).
`
`LINE VOLTAGE RANGE: 198 - 242 VAC
`POWER: 125 W MAX
`FREQ.: 47 - 63 HZ
`
`~
`220 VOLTS
`
`FOR CONTINUED FIRE PROTECTION
`REPLACE ONLY WITH 2.0A, 250 V,
`TYPE T FUSE, (PER IEC 127-2/III).
`
`LINE VOLTAGE RANGE: 216 - 264 VAC
`POWER: 125 W MAX
`FREQ.: 47 - 63 HZ
`
`~
`240 VOLTS
`
`On/OFF Switch
`
`Fuse:
`115 V – 4 amp, slo-blo
`220 V – 2 amp, slo-blo
`
` Note: For maximum life of the mercury vapor
`(cid:5)
`lamp:
`
`Always operate the light source in its upright
`position.
`
`If you are going to use the light source more
`than once during the day, leave it on. Lamp
`wear results more from turning the light source
`on and off than from steady operation.
`
`(cid:1) (cid:2)
`
`Introduction
`
`The PASCO scientific Model OS-9286A Mercury Vapor
`Light Source provides approximately 3,000 lumens of
`light in the mercury spectrum. The 100 watt light source
`comes ready to use, with a built-in power supply so the
`unit can be powered from a standard 115 VAC, 60 Hz
`outlet (OS-9286A-220 is powered from a 220 VAC, 50
`Hz outlet). Cooling fins and air vents on the sturdy alu-
`minum case ensure cool, safe operation. In addition, rails
`on the front and rear of the case can be used for mounting
`standard 2-inch by 2-inch filters, so that monochromatic
`light can be obtained.
`
`© 1990 PASCO scientific
`This instruction sheet edited by: Dave Griffith
`
`10101 Foothills Blvd. • P.O. Box 619011 • Roseville, CA 95678-9011 USA
`Phone (916) 786-3800 • FAX (916) 786-8905 • email: techsupp@PASCO.com
`
`1
`
`better
`ways to
`
`teach physics
`
`ASML 1230
`ASML 1029
`
`

`
`Mercury Vapor Light Source
`
`012-02262H
`
`400
`
`U.V.
`
`480
`
`NOTE: U.V. is
`blocked by the
`outer glass
`envelope.
`
`Green
`
`Blue
`
`Yellow
`
`Violet 1
`
`300
`
`200
`
`mW
`5 nm
`
`100
`
`Violet 2
`
`300
`
`500
`400
`Wavelength (nm)
`Spectral Power Distribution per 1000 Lumens
`
`600
`
`Color
`
`Frequency (Hz) Wavelength (nm)
`
`Yellow
`
`Green
`
`Blue
`
`Violet
`
`5.18672E+14
`
`5.48996E+14
`
`6.87858E+14
`
`7.40858E+14
`
`Ultraviolet
`
`8.20264E+14
`
`578
`
`546.074
`
`435.835
`
`404.656
`
`365.483
`
`Wavelength of the Mercury Spectral Lines
`
`All values except wavelength for yellow line are
`from Handbook of Chemistry and Physics, 46th ed.
`The wavelength of the yellow was determined ex-
`perimentally using a 600 line/mm grating.
`NOTE: The yellow line is actually a doublet with
`(cid:5)
`wavelengths of 578 and 580nm.
`
`To Operate the Light Source:
`Simply plug it into a standard, grounded, 115 VAC (or
`220VAC) outlet; then flip the switch on the front of the
`light source to ON.
`
`CAUTION: The outer glass tube of the mercury
`(cid:5)
`vapor lamp blocks harmful ultraviolet radiation
`produced by the lamp. If the outer tube is cracked
`or broken, this radiation can cause severe skin
`burn and produce eye inflammation. Regularly
`inspect the outer tube for cracks, especially if the
`light source has received a significant jolt. If the
`glass bulb is broken, immediately turn lamp off and
`remove it to avoid possible injury. Replace Bulb
`prior to next use.
`
`CAUTION
`RISK OF ELECTRIC SHOCK
`DO NOT OPEN
`
`CAUTION:
`TO PREVENT THE RISK OF ELECTRIC SHOCK, DO
`NOT REMOVE COVER ON UNIT. NO USER SERVICE-
`ABLE PARTS INSIDE. REFER SERVICING TO QUALI-
`FIED SERVICE PERSONNEL.
`
`The lightning flash with arrowhead, within
`an equilateral triangle, is intended to alert
`the user of the presence of uninsulated
`“dangerous voltage” within the product’s
`enclosure that may be of sufficient magni-
`tude to constitute a risk of electric shock to
`persons.
`
`The exclamation point within an equi-
`lateral triangle is intended to alert the
`user of the presence of important oper-
`ating and maintenance (servicing) in-
`structions in the literature accompany-
`ing the appliance.
`
`Maintenance
`The light source lamp can be expected to provide
`24,000+ hours of trouble free operation. However, if the
`light at any time fails to come on, first check the fuse on
`the front of the light source case. If the fuse is not
`blown, you may need to replace the lamp. In rare cases,
`the problem may be with the ballast. However, ballast
`replacement should be performed only by experienced
`personnel. If the fuse is intact and replacing the bulb
`does not restore operation, we recommend you return the
`unit to PASCO scientific for repair.
`
`CAUTION—HIGH VOLTAGE: Do not open the
`(cid:5)
`light source with the unit plugged in.
`
`2
`

`
`

`
`012-02262H
`
`Mercury Vapor Light Source
`
`To Replace the Mercury Vapor Lamp:
`
`Other PASCO Spectral Equipment
`
`PASCO scientific offers a variety of student spectral
`light sources, and a precision student spectrometer for
`accurate spectral measurements in the student lab. For
`more information, check the current PASCO catalog,
`or call toll-free at 1-800-772-8700. Outside the United
`States call 1-916-786-3800.
`
`DS1
`100 W
`HG
`
`DS1
`100 W
`HG
`
`Unplug the light source. Allow 10 to 15 minutes for
`the lamp to cool.
`Unscrew the eight screws that attach the top plate of
`the light source and remove the top plate.
`Using a glove or several folds of thick cloth to protect
`your hand, unscrew the lamp. Discard it as you would
`any broken glass.
`
`(cid:2)(cid:1)
`
`(cid:3)
`
`(cid:4)
`
`Replace the lamp and the top plate of the light source.
`
`Replacement Parts
`
`Only the following replacement parts should be used:
`
`Description
`
`OS-9286A
`
`Pasco #
`
`Hg Lamp GE HR100A38
`
`526-018
`
`Hg Lamp Ballast
`
`322-019
`
`Fuse (5x20) 4 amp, slo-blo
`
`530-035
`
`OS-9286A-220
`
`Hg Lamp GE HR100A38
`
`526-018
`
`Hg Lamp Ballast
`
`322-028
`
`Fuse (5x20) 2 amp, slo-blo
`
`530-036
`
`F1
`
`S1
`
`OS-9286A
`
`4 A
`
`115 VAC
`
`T1
`
`OS-9286A-220
`
`220 VAC
`

`
`N/C (240 V TAP)
`
`F1
`
`S1
`
`2 A
`
`T1
`
`Schematic
`
`3
`
`

`
`Mercury Vapor Light Source
`
`012-02262H
`
`Warranty and Equipment Return
`
`Limited Warranty
`
`Equipment Return
`
`PASCO scientific warrants this product to be free from
`defects in materials and workmanship for a period of one
`year from the date of shipment to the customer. PASCO
`will repair or replace, at its option, any part of the product
`which is deemed to be defective in material or workman-
`ship. This warranty does not cover damage to the product
`caused by abuse or improper use. Determination of
`whether a product failure is the result of a manufacturing
`defect or improper use by the customer shall be made
`solely by PASCO scientific. Responsibility for the return
`of equipment for warranty repair belongs to the customer.
`Equipment must be properly packed to prevent damage
`and shipped postage or freight prepaid. (Damage caused
`by improper packing of the equipment for return ship-
`ment will not be covered by the warranty.) Shipping
`costs for returning the equipment, after repair, will be
`paid by PASCO scientific.
`
`Should this product have to be returned to PASCO scien-
`tific, for whatever reason, notify PASCO scientific by
`letter or phone BEFORE returning the product. Upon
`notification, the return authorization and shipping instruc-
`tions will be promptly issued.
`
`NOTE:
`(cid:5)
`NO EQUIPMENT WILL BE ACCEPTED FOR
`RETURN WITHOUT AN AUTHORIZATION.
`
`When returning equipment for repair, the units must be
`packed properly. Carriers will not accept responsibility
`for damage caused by improper packing. To be certain
`the unit will not be damaged in shipment, observe the fol-
`lowing rules:
`
`(cid:1) The carton must be strong enough for the item
`shipped.
`(cid:2) Make certain there is at least two inches of packing
`material between any point on the apparatus and the
`inside walls of the carton.
`(cid:3) Make certain that the packing material can not shift
`in the box, or become compressed, thus letting the
`instrument come in contact with the edge of the box.
`
`Address:
`
`PASCO scientific
`
`10101 Foothills Blvd.
`
`P.O. Box 619011
`
`Roseville, CA 95678-9011
`
`Phone:
`
`FAX:
`
`(916) 786-3800
`
`(916) 786-8905
`
`4
`

This document is available on Docket Alarm but you must sign up to view it.


Or .

Accessing this document will incur an additional charge of $.

After purchase, you can access this document again without charge.

Accept $ Charge
throbber

Still Working On It

This document is taking longer than usual to download. This can happen if we need to contact the court directly to obtain the document and their servers are running slowly.

Give it another minute or two to complete, and then try the refresh button.

throbber

A few More Minutes ... Still Working

It can take up to 5 minutes for us to download a document if the court servers are running slowly.

Thank you for your continued patience.

This document could not be displayed.

We could not find this document within its docket. Please go back to the docket page and check the link. If that does not work, go back to the docket and refresh it to pull the newest information.

Your account does not support viewing this document.

You need a Paid Account to view this document. Click here to change your account type.

Your account does not support viewing this document.

Set your membership status to view this document.

With a Docket Alarm membership, you'll get a whole lot more, including:

  • Up-to-date information for this case.
  • Email alerts whenever there is an update.
  • Full text search for other cases.
  • Get email alerts whenever a new case matches your search.

Become a Member

One Moment Please

The filing “” is large (MB) and is being downloaded.

Please refresh this page in a few minutes to see if the filing has been downloaded. The filing will also be emailed to you when the download completes.

Your document is on its way!

If you do not receive the document in five minutes, contact support at support@docketalarm.com.

Sealed Document

We are unable to display this document, it may be under a court ordered seal.

If you have proper credentials to access the file, you may proceed directly to the court's system using your government issued username and password.


Access Government Site

We are redirecting you
to a mobile optimized page.





Document Unreadable or Corrupt

Refresh this Document
Go to the Docket

We are unable to display this document.

Refresh this Document
Go to the Docket