throbber
CeraLux ® Xenon Arc Lamps
`
`LuxteL’s CeraLux series of lamps
`provide the end market with a value
`supplier of ceramic lamps, wholly made in
`the United States. Originally engineered to be
`an exact replacement for lamps designed
`to operate in existing systems employing
`this type of ceramic, xenon short arc lamp.
`Today the series has been extended
`to provide custom designed lamps for major
`OEMs and includes collimated and focused,
`filtered and UV output in wattages from
`150 to 500.
`
`CeraLux lamps are designed to give the
`instrument builder a combination of rugged
`compactness and extremely high brightness,
`excellent color temperature over life and lamp
`to lamp repeatability.
`
`
`CeraLux Xenon
`Collimated Arc Lamp
`
`CeraLux Xenon
`Focused Arc Lamp
`
`CeraLux xenon lamps produce
`broadband light with color
`temperatures of approximately
`5900°K. This results in
`excellent white light for
`photopic, video and
`photographic applications.
`
`© 2003-2004, LuxteL llc. All rights reserved.
`
`Energetiq Ex. 2076, page 1 - IPR2015-01300, IPR2015-01303
`
`

`
`CeraLux ® Xenon Focused Arc Lamps
`With Elliptical Reflector
`B Body Size
`
`PHYSICAL SPECIFICATIONS
`DESCRIPTION SPECIFICATION
`Reflector Geometry Elliptical 1 = X2/1.0592 + Y2/.502
`Window Diameter 1 inch (25.4 mm)
`Weight 150 grams
`
`Dimensions in parentheses are in millimeters
`
`OPERATIONAL SPECIFICATIONS
` CL300BF-10F CL300BUV-10F CL175BF-10F CL175BUV-10F CL125BF-10F CL125BUV-10F
`POWER (WATTS)
`Nominal 300 300 175 175 125 125
`Range 175 - 330 175 - 330 150 - 200 150 - 200 75 - 150 75 - 150
`
`CURRENT (amps DC)
`Nominal 22 22 14 14 11 11
`Range 13 - 23 13 - 23 12 - 16 12 - 16 8 - 14 8 - 14
`
`VOLTAGE (volts DC)
`Nominal 13.5 13.5 12.5 12.5 11 11
`Range 11.5 - 15 11.5 - 15 10.5 – 13.5 10.5 – 13.5 10 – 12.5 10 – 12.5
`
`Minimum Ignition Voltage (kV) 23 23 23 23 23 23
`Maximum Temperature 150°C 150°C 150°C 150°C 150°C 150°C
`
`Typical Lifetime of lamps is 1000 hours – to 50% of initial output
`
`OUTPUT AT NOMINAL POWER
`
`Radiant Output (watts) 65 65 34 34 19 19
`Visible Output (lumens) 6500 5900 2700 2500 1600 1400
`UV Output (watts) 3 9 <2 5 1 3
`IR Output (watts) 32 30 19 18 10 10
`Color Temperature (°K) 5800 5100 5800 5100 5800 5100
`
`
`
`All values and specifications subject to change without notice.
`
`
`© 2003-2004, LuxteL llc. All rights reserved.
`
`Energetiq Ex. 2076, page 2 - IPR2015-01300, IPR2015-01303
`
`

`

`CeraLux Xenon Arc Lamps
`
`•
`
`Read all safety, cooling, operational and disposal notes prior to use. Consult the factory at the numbers listed
`below for any assistance in the proper operation and use of all lamps.
`
`SAFETY
`Always take precaution when handling lamps because they are under high pressure.
`•
`The cold weld pinch-off tube is very sharp, care should be taken to not come into contact with it or disrupt it.
`•
`• During operation, the IR and UV radiation can cause skin and eye damage. Do not look directly into a lamp,
`get in the path of the output beam or touch the lamp while operating.
`Proper eye protection should be worn when handling lamps due to high pressure.
`•
`Extra care should be exercised when using lamps that produce ultraviolet radiation.
`•
`Protection of the eyes and skin should be undertaken when exposure to ultraviolet radiation is possible.
`•
`• When operating UV lamps, UV blocking eye protection should be worn during lamp operation.
`• UV lamps will produce toxic ozone due to ultraviolet radiation below 242 nm acting upon oxygen in air.
`To avoid ozone, an inert atmosphere should be used. Select a non-UV lamp (filtered “F” series” if ultraviolet
`wavelengths are not needed.
`• Due to high operating temperatures, care should be taken if handling lamps after operation.
`
`COOLING
`Proper cooling will provide optimum performance and extend life. Forced air cooling should be used.
`•
`Seal temperatures should not be allowed to exceed 200º C. Under nominal ooperating conditions attempts
`•
`should be made to maintain maximum lamp temperatures of 150 º C.
`Appropriate thermal and electrically conductive compounds should be used to promote improved thermal
`conduction between lamps and heat sinks. Do not apply thermal compounds to the lamp window or ceramic
`body. A thick layer should be applied to all surfaces that contact heat sinks.
`
`
`OPERATION
`Lamp should not be operated with window facing upwards. Keep lamp oriented to within 45º of vertical.
`•
`Lamps must be operated within stated current and voltage ranges. Overpowering can lead to electrode
`•
`wear and shortened life. Underpowering may lead to instabilities and problems starting (depending on
`power source).
`Lamps should be mounted in suitable heat sinks.
`•
`Assure proper polarity of power source when making electrical connections.
`•
`• Care should be taken when using filters or lenses that may reflect energy back into lamps.
`• Consult the factory at the numbers below for proper use and operation of all lamps.
`
`DISPOSAL
`Proper eye protection should be worn when handling lamps.
`•
`• Care must be taken due to the sharp pinch-off tube on the rear of the lamp.
`The internal pressure of the lamp may be relieved by opening the pinch-off tube with a pair of heavy pliers.
`•
`The internal gas will be heard escaping through the tube opening. The lamp may now be disposed of.
`•
`
`WARRANTY
`LuxteL’s CeraLux lamps are covered by a 500 hour warranty.
`•
`Typical lifetime is 1000 hours (50% of initial output).
`•
`
`
`LuxteL® llc
`100 Ferncroft Road ~ Danvers, MA 01923 USA
`Tel. 978.774.9136 ~ Fax. 978.774.1559
`Email: info@luxtel.net / Web: http://www.luxtel.net
`
`© 2003-2004, LuxteL llc. All rights reserved.
`
`Energetiq Ex. 2076, page 3 - IPR2015-01300, IPR2015-01303

This document is available on Docket Alarm but you must sign up to view it.


Or .

Accessing this document will incur an additional charge of $.

After purchase, you can access this document again without charge.

Accept $ Charge
throbber

Still Working On It

This document is taking longer than usual to download. This can happen if we need to contact the court directly to obtain the document and their servers are running slowly.

Give it another minute or two to complete, and then try the refresh button.

throbber

A few More Minutes ... Still Working

It can take up to 5 minutes for us to download a document if the court servers are running slowly.

Thank you for your continued patience.

This document could not be displayed.

We could not find this document within its docket. Please go back to the docket page and check the link. If that does not work, go back to the docket and refresh it to pull the newest information.

Your account does not support viewing this document.

You need a Paid Account to view this document. Click here to change your account type.

Your account does not support viewing this document.

Set your membership status to view this document.

With a Docket Alarm membership, you'll get a whole lot more, including:

  • Up-to-date information for this case.
  • Email alerts whenever there is an update.
  • Full text search for other cases.
  • Get email alerts whenever a new case matches your search.

Become a Member

One Moment Please

The filing “” is large (MB) and is being downloaded.

Please refresh this page in a few minutes to see if the filing has been downloaded. The filing will also be emailed to you when the download completes.

Your document is on its way!

If you do not receive the document in five minutes, contact support at support@docketalarm.com.

Sealed Document

We are unable to display this document, it may be under a court ordered seal.

If you have proper credentials to access the file, you may proceed directly to the court's system using your government issued username and password.


Access Government Site

We are redirecting you
to a mobile optimized page.





Document Unreadable or Corrupt

Refresh this Document
Go to the Docket

We are unable to display this document.

Refresh this Document
Go to the Docket